ThyristorCenterTapmPulse_RL2*m pulse thyristor rectifier with center tap and R-L load |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
This example shows a controlled m
pulse center tap rectifier with R-L load, where m
is the number of phases.
Plot current currentSensor.i
, average current meanCurrent.y
, voltage voltageSensor.v
and average voltage meanVoltage.v
.
m |
Value: 3 Type: Integer Description: Number of phases |
---|---|
Vrms |
Value: 110 Type: Voltage (V) Description: RMS supply voltage |
f |
Value: 50 Type: Frequency (Hz) Description: Frequency |
constantFiringAngle |
Value: 30 * pi / 180 Type: Angle (rad) Description: Firing angle |
R |
Value: 20 Type: Resistance (Ω) Description: Load resistance |
L |
Value: 1 Type: Inductance (H) Description: Load resistance |
ground |
Type: Ground |
|
---|---|---|
star |
Type: Star |
|
sineVoltage_p |
Type: SineVoltage |
|
rectifier |
Type: ThyristorCenterTapmPulse |
|
voltagesensor |
Type: VoltageSensor |
|
meanVoltage |
Type: Mean |
|
rootMeanSquareVoltage |
Type: RootMeanSquare |
|
currentSensor |
Type: CurrentSensor |
|
meanCurrent |
Type: Mean |
|
pulsem |
Type: VoltageBridge2mPulse |
|
resistor |
Type: Resistor |
|
inductor |
Type: Inductor |