MultiStarResistance

Resistance connection of star points

Diagram

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

Multi star points are connected by resistors. This model is required to operate polyphase systems with even phase numbers to avoid ideal connections of start points of base systems; see polyphase guidelines.

Parameters (3)

m

Value: 3

Type: Integer

Description: Number of phases

mBasic

Value: Modelica.Electrical.Polyphase.Functions.numberOfSymmetricBaseSystems(m)

Type: Integer

Description: Number of symmetric base systems

R

Value: 1e6

Type: Resistance (Ω)

Description: Insulation resistance between base systems

Connectors (2)

plug

Type: PositivePlug

pin

Type: NegativePin

Components (3)

multiStar

Type: MultiStar

resistor

Type: Resistor

star

Type: Star