IMC_TransformerInduction machine with squirrel cage starting with transformer |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
At start time tStart1 three-phase voltage is supplied to the induction machine with squirrel cage via the transformer; the machine starts from standstill, accelerating inertias against load torque quadratic dependent on speed; at start time tStart2 the machine is fed directly from the voltage source, finally reaching nominal speed.
Simulate for 2.5 seconds and plot (versus time):
Default machine parameters are used.
VNominal |
Value: 100 Type: Voltage (V) Description: Nominal RMS voltage per phase |
---|---|
fNominal |
Value: aimcData.fsNominal Type: Frequency (Hz) Description: Nominal frequency |
tStart1 |
Value: 0.1 Type: Time (s) Description: Start time |
tStart2 |
Value: 2.0 Type: Time (s) Description: Start time of bypass transformer |
TLoad |
Value: 161.4 Type: Torque (N·m) Description: Nominal load torque |
wLoad |
Value: 1440.45 * 2 * Modelica.Constants.pi / 60 Type: AngularVelocity (rad/s) Description: Nominal load speed |
JLoad |
Value: 0.29 Type: Inertia (kg·m²) Description: Load's moment of inertia |
transformerData |
Value: Type: TransformerData Description: Transformer data |
aimcData |
Value: Type: IM_SquirrelCageData Description: Induction machine data |
aimc |
Type: IM_SquirrelCage |
|
---|---|---|
currentQuasiRMSSensor |
Type: CurrentQuasiRMSSensor |
|
sineVoltage |
Type: SineVoltage |
|
star |
Type: Star |
|
ground |
Type: Ground |
|
booleanStep1 |
Type: BooleanStep[m] |
|
idealCloser |
Type: IdealClosingSwitch |
|
transformer |
Type: Yy00 |
|
ground2 |
Type: Ground |
|
transformerData |
Type: TransformerData Description: Transformer data |
|
booleanStep2 |
Type: BooleanStep[m] |
|
idealCommutingSwitch |
Type: IdealCommutingSwitch |
|
loadInertia |
Type: Inertia |
|
quadraticLoadTorque | ||
terminalBox |
Type: TerminalBox |
|
aimcData |
Type: IM_SquirrelCageData Description: Induction machine data |