SMEE_GeneratorElectrical excited synchronous machine operating as generator |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
An electrically excited synchronous generator is connected to the grid and driven with constant speed. Since speed is slightly smaller than synchronous speed corresponding to mains frequency, rotor angle is very slowly increased. This allows to see several characteristics dependent on rotor angle.
Simulate for 30 seconds and plot (versus rotorAngleM.rotorDisplacementAngle
):
speedM|E.tauElectrical
: machine torquemechanicalPowerSensorM|E.P
: mechanical powerVsNominal |
Value: 100 Type: Voltage (V) Description: Nominal RMS voltage per phase |
---|---|
fsNominal |
Value: smeeData.fsNominal Type: Frequency (Hz) Description: Nominal frequency |
w |
Value: Modelica.Units.Conversions.from_rpm(1499) Type: AngularVelocity (rad/s) Description: Nominal speed |
Ie |
Value: 19 Type: Current (A) Description: Excitation current |
Ie0 |
Value: 10 Type: Current (A) Description: Initial excitation current |
gamma0 |
Value: 0 Type: Angle (rad) Description: Initial rotor displacement angle |
p |
Value: 2 Type: Integer Description: Number of pole pairs |
Rs |
Value: 0.03 Type: Resistance (Ω) Description: Warm stator resistance per phase |
Lssigma |
Value: 0.1 / (2 * Modelica.Constants.pi * fsNominal) Type: Inductance (H) Description: Stator stray inductance per phase |
Lmd |
Value: 1.5 / (2 * Modelica.Constants.pi * fsNominal) Type: Inductance (H) Description: Main field inductance in d-axis |
Lmq |
Value: 1.5 / (2 * Modelica.Constants.pi * fsNominal) Type: Inductance (H) Description: Main field inductance in q-axis |
Lrsigmad |
Value: 0.05 / (2 * Modelica.Constants.pi * fsNominal) Type: Inductance (H) Description: Damper stray inductance (equivalent three-phase winding) d-axis |
Lrsigmaq |
Value: Lrsigmad Type: Inductance (H) Description: Damper stray inductance (equivalent three-phase winding) q-axis |
Rrd |
Value: 0.04 Type: Resistance (Ω) Description: Warm damper resistance (equivalent three-phase winding) d-axis |
Rrq |
Value: Rrd Type: Resistance (Ω) Description: Warm damper resistance (equivalent three-phase winding) q-axis |
smeeData |
Value: Type: SynchronousMachineData Description: Synchronous machine data |
star |
Type: Star |
|
---|---|---|
ground |
Type: Ground |
|
sineVoltage |
Type: SineVoltage |
|
electricalPowerSensorM |
Type: ElectricalPowerSensor |
|
electricalPowerSensorE |
Type: ElectricalPowerSensor |
|
terminalBoxM |
Type: TerminalBox |
|
terminalBoxE |
Type: TerminalBox |
|
smeeM |
Type: SM_ElectricalExcited |
|
smeeE |
Type: SM_ElectricalExcited |
|
groundM |
Type: Ground |
|
groundE |
Type: Ground |
|
rampCurrentM |
Type: RampCurrent |
|
rampCurrentE |
Type: RampCurrent |
|
rotorAngleM |
Type: RotorDisplacementAngle |
|
rotorAngleE |
Type: RotorDisplacementAngle |
|
mechanicalPowerSensorM |
Type: MechanicalPowerSensor |
|
mechanicalPowerSensorE |
Type: MechanicalPowerSensor |
|
constantSpeedM |
Type: ConstantSpeed |
|
constantSpeedE |
Type: ConstantSpeed |
|
smeeData |
Type: SynchronousMachineData Description: Synchronous machine data |