VariablePermeance

Variable permeance

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

This constant permeance is provided for test purposes and simple magnetic network models. The permeance is not calculated from geometry and permeability of a flux tube, but is provided as parameter.

Connectors (3)

port_p

Type: PositiveMagneticPort

Description: Positive quasi-static magnetic port

port_n

Type: NegativeMagneticPort

Description: Negative quasi-static magnetic port

G_m

Type: RealInput

Description: Magnetic permeance

Components (2)

V_m

Type: ComplexMagneticPotentialDifference

Description: Magnetic potential difference of both ports

Phi

Type: ComplexMagneticFlux

Description: Magnetic flux from port_p to port_n