GenericFluxTube

Flux tube with fixed cross-section, fixed length and linear material characteristics

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

The generic flux tube models the reluctance with constant area of cross section, and length, l the magnetic reluctance by:

,

Parameters (3)

mu_rConst

Value: 1

Type: RelativePermeability

Description: Constant relative permeability

l

Value: 0.01

Type: Length (m)

Description: Length in direction of flux

area

Value: 0.0001

Type: CrossSection (m²)

Description: Area of cross section

Connectors (2)

port_p

Type: PositiveMagneticPort

Description: Positive quasi-static magnetic port

port_n

Type: NegativeMagneticPort

Description: Negative quasi-static magnetic port

Components (4)

V_m

Type: ComplexMagneticPotentialDifference

Description: Magnetic potential difference of both ports

Phi

Type: ComplexMagneticFlux

Description: Magnetic flux from port_p to port_n

B

Type: ComplexMagneticFluxDensity

Description: Magnetic flux density (normal component)

H

Type: ComplexMagneticFieldStrength

Description: Magnetic field strength (normal component)

Used in Examples (2)

LinearInductor

Modelica.Magnetic.QuasiStatic.FluxTubes.Examples

Linear inductor with ferromagnetic core

NonLinearInductor

Modelica.Magnetic.QuasiStatic.FluxTubes.Examples

Non linear inductor with ferromagnetic core