Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.InductionMachines.ComparisonPolyphase

Compare polyphase machines with three-phase machines

Information

Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).

Package Content

Name Description
Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.InductionMachines.ComparisonPolyphase.IMC_DOL_Polyphase IMC_DOL_Polyphase Direct on line start of polyphase induction machine with squirrel cage
Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.InductionMachines.ComparisonPolyphase.IMS_Start_Polyphase IMS_Start_Polyphase Starting of polyphase induction machine with slip rings
Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.InductionMachines.ComparisonPolyphase.IMC_DOL_CommonLeakage IMC_DOL_CommonLeakage Direct on line start of polyphase induction machine with squirrel cage

Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.InductionMachines.ComparisonPolyphase.IMC_DOL_Polyphase Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.InductionMachines.ComparisonPolyphase.IMC_DOL_Polyphase

Direct on line start of polyphase induction machine with squirrel cage

Information

At start time tStart voltages are supplied to the polyphase induction machines with squirrel cage. The machines starts from standstill, accelerating inertias against load torque quadratic dependent on speed, finally reaching nominal speed. Two equivalent machines with different numbers of phases are compared and their equal behavior is demonstrated.

Simulate for 1.5 seconds and plot (versus time):

Extends from Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
mNumber of stator phases
VsNominalNominal RMS voltage per phase [V]
fNominalNominal frequency [Hz]
tOnStart time of machine [s]
T_LoadNominal load torque [N.m]
w_LoadNominal load speed [rad/s]
J_LoadLoad inertia [kg.m2]
pNumber of pole pairs
aimcData3Induction machine data of a three-phase machine
aimcDataMInduction machine data of an m-phase machine

Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.InductionMachines.ComparisonPolyphase.IMS_Start_Polyphase Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.InductionMachines.ComparisonPolyphase.IMS_Start_Polyphase

Starting of polyphase induction machine with slip rings

Information

At start time tOn voltages are supplied to the induction machines with sliprings. The two machine start from standstill, accelerating inertias against load torque quadratic dependent on speed, using a starting resistance. At time tRheostat external rotor resistance is shortened, finally reaching nominal speed. Two equivalent machines with different numbers of phases are compared and their equal behavior is demonstrated.

Simulate for 1.5 seconds and plot (versus time):

Extends from Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
mNumber of stator phases
mrNumber of rotor phases
VsNominalNominal RMS voltage per phase [V]
fNominalNominal frequency [Hz]
tOnStart time of machine [s]
RStartStarting resistance [Ohm]
tRheostatTime of shortening the rheostat [s]
T_LoadNominal load torque [N.m]
w_LoadNominal load speed [rad/s]
J_LoadLoad inertia [kg.m2]
aimsData3Induction machine data of a three-phase machine
aimsDataMInduction machine data of an m-phase machine

Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.InductionMachines.ComparisonPolyphase.IMC_DOL_CommonLeakage Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.InductionMachines.ComparisonPolyphase.IMC_DOL_CommonLeakage

Direct on line start of polyphase induction machine with squirrel cage

Information

At start time tStart voltages are supplied to the polyphase induction machines with squirrel cage. The machines starts from standstill, accelerating inertias against load torque quadratic dependent on speed, finally reaching nominal speed. Three equivalent machines with different parameter ratioCommonLeakage are compared. Note that due to the mode of operation, the behaviour of all three machines is identical. Only when fed by switching power electronics, parameter ratioCommonLeakage is essential.

Extends from Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
mNumber of stator phases
VsNominalNominal RMS voltage per phase [V]
fNominalNominal frequency [Hz]
tOnStart time of machine [s]
T_LoadNominal load torque [N.m]
w_LoadNominal load speed [rad/s]
J_LoadLoad inertia [kg.m2]
aimcDataInduction machine data
Automatically generated Tue Feb 24 16:59:23 2026.