.Modelica.Fluid.Dissipation.PressureLoss.Bend.dp_curvedOverall_DP

Information

Calculation of pressure loss in curved bends at overall flow regime for incompressible and single-phase fluid flow through circular cross sectional area considering surface roughness.

Generally this function is numerically best used for the incompressible case , where the mass flow rate (m_flow) is known (as state variable) in the used model and the corresponding pressure loss (DP) has to be calculated. On the other hand the function dp_curvedOverall_MFLOW is numerically best used for the compressible case if the pressure loss (dp) is known (out of pressures as state variable) and the mass flow rate (M_FLOW) has to be calculated. See more information.

Interface

function dp_curvedOverall_DP
  extends Modelica.Icons.Function;
  import FD = Modelica.Fluid.Dissipation.PressureLoss.Bend;
  import SMOOTH = Modelica.Fluid.Dissipation.Utilities.Functions.General.Stepsmoother;
  input Modelica.Fluid.Dissipation.PressureLoss.Bend.dp_curvedOverall_IN_con IN_con "Input record for function dp_curvedOverall_DP" annotation(
    Dialog(group = "Constant inputs"));
  input Modelica.Fluid.Dissipation.PressureLoss.Bend.dp_curvedOverall_IN_var IN_var "Input record for function dp_curvedOverall_DP" annotation(
    Dialog(group = "Variable inputs"));
  input SI.MassFlowRate m_flow "Mass flow rate" annotation(
    Dialog(group = "Input"));
  output SI.Pressure DP "Output for function dp_curvedOverall_DP";
end dp_curvedOverall_DP;

Revisions

2014-12-12 Stefan Wischhusen: Factor A2 corrected for R/D > 0.55-0.7. The factor is now 6e3 instead of 4e3.

Generated at 2020-06-05T07:38:22Z by OpenModelica 1.16.0~dev-420-gc007a39