Calculation of pressure loss for a valve with different geometries at overall flow regime for incompressible and single-phase fluid flow in dependence of its opening.
Generally this function is numerically best used for the incompressible case , where the mass flow rate (m_flow) is known (as state variable) in the used model and the corresponding pressure loss (DP) has to be calculated. On the other hand the function dp_severalGeometryOverall_MFLOW is numerically best used for the compressible case if the pressure loss (dp) is known (out of pressures as state variable) and the mass flow rate (M_FLOW) has to be calculated. See more information.
function dp_severalGeometryOverall_DP extends Modelica.Icons.Function; import FD = Modelica.Fluid.Dissipation.PressureLoss.Valve; import SMOOTH = Modelica.Fluid.Dissipation.Utilities.Functions.General.Stepsmoother; import TYP = Modelica.Fluid.Dissipation.Utilities.Types; input Modelica.Fluid.Dissipation.PressureLoss.Valve.dp_severalGeometryOverall_IN_con IN_con "Input record for function dp_severalGeometryOverall_DP" annotation( Dialog(group = "Constant inputs")); input Modelica.Fluid.Dissipation.PressureLoss.Valve.dp_severalGeometryOverall_IN_var IN_var "Input record for function dp_severalGeometryOverall_DP" annotation( Dialog(group = "Variable inputs")); input SI.MassFlowRate m_flow "Mass flow rate" annotation( Dialog(group = "Input")); output SI.Pressure DP "Pressure loss"; end dp_severalGeometryOverall_DP;