.Modelica.Fluid.Dissipation.Utilities.SharedDocumentation.HeatTransfer.HelicalPipe.kc_turbulent

Information

Calculation of the mean convective heat transfer coefficient kc of a helical pipe for turbulent flow regime.

Functions kc_turbulent and kc_turbulent_KC

There are basically three differences:

The critical Reynolds number Re_crit in a helical pipe depends on its mean curvature diameter. The smaller the mean curvature diameter of the helical pipe d_mean , the earlier the turbulent regime will start due to vortexes out of higher centrifugal forces.

Geometry

pic_helicalPipe

Calculation

The mean convective heat transfer coefficient kc for helical pipes is calculated through the corresponding Nusselt number Nu according to [VDI 2002, p. Ga 2, eq. 6]:

    Nu = (zeta_TOT/8)*Re*Pr/{1 + 12.7*(zeta_TOT/8)^0.5*[Pr^(2/3)-1]},

where the influence of the pressure loss on the heat transfer calculation is considered through

    zeta_TOT = 0.3164*Re^(-0.25) + 0.03*(d_hyd/d_coil)^(0.5) and

and the resulting mean convective heat transfer coefficient kc

    kc =  Nu * lambda / d_hyd

with

d_mean as mean diameter of helical pipe [m],
d_coil = f(geometry) as mean curvature diameter of helical pipe [m],
d_hyd as hydraulic diameter of the helical pipe [m],
h as slope of helical pipe [m],
kc as mean convective heat transfer coefficient [W/(m2K)],
lambda as heat conductivity of fluid [W/(mK)],
L as total length of helical pipe [m],
Nu = kc*d_hyd/lambda as mean Nusselt number [-],
Pr = eta*cp/lambda as Prandtl number [-],
Re = rho*v*d_hyd/eta as Reynolds number [-],
Re_crit = f(geometry) as critical Reynolds number [-].

Verification

The mean Nusselt number Nu representing the mean convective heat transfer coefficient kc is shown below for different numbers of turns n_nt at constant total length of the helical pipe.

fig_helicalPipe_kc_turbulent

The convective heat transfer of a helical pipe is enhanced compared to a straight pipe due to occurring turbulences resulting out of centrifugal forces. The higher the number of turns, the better is the convective heat transfer for the same length of a pipe.

Note that the ratio of hydraulic diameter to total length of helical pipe d_hyd/L has no remarkable influence on the coefficient of heat transfer kc .

References

GNIELINSKI, V.:
Heat transfer and pressure drop in helically coiled tubes.. In 8th International Heat Transfer Conference, volume 6, pages 2847?2854, Washington,1986. Hemisphere.

Generated at 2020-06-05T07:38:22Z by OpenModelica 1.16.0~dev-420-gc007a39