With this example, the controller of a tank filling/emptying
system is demonstrated.
The basic operation is to fill and empty the two tanks:
- Valve 1 is opened and tank 1 is filled.
- When tank 1 reaches its fill level limit, valve 1 is
closed.
- After a waiting time, valve 2 is opened and the fluid flows
from tank 1 into tank 2.
- When tank 1 reaches its minimum level, valve 2 is closed.
- After a waiting time, valve 3 is opened and the fluid flows out
of tank 2
- When tank 2 reaches its minimum level, valve 3 is closed
The above "normal" process can be influenced by three
buttons:
- Button start starts the above process. When
this button is pressed after a "stop" or "shut" operation, the
process operation continues.
- Button stop stops the above process by closing
all valves. Then, the controller waits for further input (either
"start" or "shut" operation).
- Button shut is used to shutdown the process,
by emptying at once both tanks by opening valve 2 and valve 3. When
this is achieved, the process goes back to its start configuration
where all 3 valves are closed. Clicking on "start", restarts the
process.
The demo-run uses the following button presses:
- Button start pressed at 20 s.
- Button stop pressed at 220 s
- Button start pressed at 280 s
- Button stop pressed at 650 s
- Button shut pressed at 700 s
- Simulate for 900 s
This example is based on
- Dressler I. (2004):
- Code Generation From JGrafchart to Modelica.
Master thesis, supervisor: Karl-Erik Årzén, Department of Automatic
Control, Lund Institute of Technology, Lund, Sweden, March 30,
2004