.Modelica.Fluid.Machines.BaseClasses.PumpCharacteristics.linearFlow

Information

Linear flow characteristic

Interface

function linearFlow
  extends baseFlow;
  input SI.VolumeFlowRate V_flow_nominal[2] "Volume flow rate for two operating points (single pump)" annotation(
    Dialog);
  input SI.Position head_nominal[2] "Pump head for two operating points" annotation(
    Dialog);
end linearFlow;