.Modelica.Fluid.Pipes.BaseClasses.WallFriction.LaminarAndQuadraticTurbulent

Information

This component defines the quadratic turbulent regime of wall friction: dp = k*m_flow*|m_flow|, where "k" depends on density and the roughness of the pipe and is no longer a function of the Reynolds number. This relationship is only valid for large Reynolds numbers. At Re=4000, a polynomial is constructed that approaches the constant λ (for large Reynolds-numbers) at Re=4000 smoothly and has a derivative at zero mass flow rate that is identical to laminar wall friction.

Contents

Name Description
 massFlowRate_dp Return mass flow rate m_flow as function of pressure loss dp, i.e., m_flow = f(dp), due to wall friction
 pressureLoss_m_flow Return pressure loss dp as function of mass flow rate m_flow, i.e., dp = f(m_flow), due to wall friction
 massFlowRate_dp_staticHead Return mass flow rate m_flow as function of pressure loss dp, i.e., m_flow = f(dp), due to wall friction and static head
 pressureLoss_m_flow_staticHead Return pressure loss dp as function of mass flow rate m_flow, i.e., dp = f(m_flow), due to wall friction and static head
 Internal Functions to calculate mass flow rate from friction pressure drop and vice versa