.Modelica.Fluid.Vessels.OpenTank

Information

Model of a tank that is open to the ambient at the fixed pressure p_ambient.

The vector of connectors ports represents fluid ports at configurable heights, relative to the bottom of tank. Fluid can flow either out of or in to each port.

The following assumptions are made:

The port pressures represent the pressures just after the outlet (or just before the inlet) in the attached pipe. The hydraulic resistances portsData.zeta_in and portsData.zeta_out determine the dissipative pressure drop between tank and port depending on the direction of mass flow. See VesselPortsData and [Idelchik, Handbook of Hydraulic Resistance, 2004].

With the setting use_portsData=false, the port pressure represents the static head at the height of the respective port. The relationship between pressure drop and mass flow rate at the port must then be provided by connected components; Heights of ports as well as kinetic and potential energy of fluid entering or leaving are not taken into account anymore.

Revisions


Generated at 2020-06-05T07:38:22Z by OpenModelica 1.16.0~dev-420-gc007a39