Package Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords
Parameter records

Information

This icon indicates a package that contains records

Extends from Modelica.​Icons.​RecordsPackage (Icon for package containing records).

Package Contents

NameDescription
AIM_SlipRingDataCommon parameters for asynchronous induction machines with slip ring
AIM_SquirrelCageDataCommon parameters for asynchronous induction machines with squirrel cage
DcElectricalExcitedDataCommon parameters for DC machines
DcPermanentMagnetDataCommon parameters for DC machines
DcSeriesExcitedDataCommon parameters for DC machines
InductionMachineDataCommon parameters for induction machines
SM_ElectricalExcitedDataCommon parameters for synchronous induction machines with electrical excitation
SM_PermanentMagnetDataCommon parameters for synchronous induction machines with permanent magnet
SM_ReluctanceRotorDataCommon parameters for synchronous induction machines with reluctance rotor
TransformerDataCommon parameters for transformers

Record Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​InductionMachineData
Common parameters for induction machines

Information

Basic parameters of induction machines are predefined with default values.

Extends from Modelica.​Icons.​Record (Icon for records).

Fields

TypeNameDescription
parameter IntegermNumber of phases
parameter InertiaJrRotor's moment of inertia
parameter InertiaJsStator's moment of inertia
parameter IntegerpNumber of pole pairs (Integer)
parameter FrequencyfsNominalNominal frequency
parameter ResistanceRsStator resistance per phase at TRef
parameter TemperatureTsRefReference temperature of stator resistance
parameter LinearTemperatureCoefficient20alpha20sTemperature coefficient of stator resistance at 20 degC
parameter RealeffectiveStatorTurnsEffective number of stator turns
parameter InductanceLszeroStator zero sequence inductance
parameter InductanceLssigmaStator stray inductance per phase
parameter FrictionParametersfrictionParametersFriction loss parameter record
parameter CoreParametersstatorCoreParametersStator core loss parameter record; all parameters refer to stator side
parameter StrayLoadParametersstrayLoadParametersStray load losses

Record Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​AIM_SquirrelCageData
Common parameters for asynchronous induction machines with squirrel cage

Information

Basic parameters of asynchronous induction machines with squirrel cage are predefined with default values.

Extends from Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​InductionMachineData (Common parameters for induction machines).

Fields

TypeNameDescription
parameter IntegermNumber of phases
parameter InertiaJrRotor's moment of inertia
parameter InertiaJsStator's moment of inertia
parameter IntegerpNumber of pole pairs (Integer)
parameter FrequencyfsNominalNominal frequency
parameter ResistanceRsStator resistance per phase at TRef
parameter TemperatureTsRefReference temperature of stator resistance
parameter LinearTemperatureCoefficient20alpha20sTemperature coefficient of stator resistance at 20 degC
parameter RealeffectiveStatorTurnsEffective number of stator turns
parameter InductanceLszeroStator zero sequence inductance
parameter InductanceLssigmaStator stray inductance per phase
parameter FrictionParametersfrictionParametersFriction loss parameter record
parameter CoreParametersstatorCoreParametersStator core loss parameter record; all parameters refer to stator side
parameter StrayLoadParametersstrayLoadParametersStray load losses
parameter InductanceLmStator main field inductance per phase
parameter InductanceLrsigmaRotor stray inductance per phase (equivalent three phase winding)
parameter ResistanceRrRotor resistance per phase (equivalent three phase winding) at TRef
parameter TemperatureTrRefReference temperature of rotor resistance
parameter LinearTemperatureCoefficient20alpha20rTemperature coefficient of rotor resistance at 20 degC

Record Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​AIM_SlipRingData
Common parameters for asynchronous induction machines with slip ring

Information

Basic parameters of asynchronous induction machines with slip ring are predefined with default values.

Extends from Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​InductionMachineData (Common parameters for induction machines).

Fields

TypeNameDescription
parameter IntegermNumber of phases
parameter InertiaJrRotor's moment of inertia
parameter InertiaJsStator's moment of inertia
parameter IntegerpNumber of pole pairs (Integer)
parameter FrequencyfsNominalNominal frequency
parameter ResistanceRsStator resistance per phase at TRef
parameter TemperatureTsRefReference temperature of stator resistance
parameter LinearTemperatureCoefficient20alpha20sTemperature coefficient of stator resistance at 20 degC
parameter RealeffectiveStatorTurnsEffective number of stator turns
parameter InductanceLszeroStator zero sequence inductance
parameter InductanceLssigmaStator stray inductance per phase
parameter FrictionParametersfrictionParametersFriction loss parameter record
parameter CoreParametersstatorCoreParametersStator core loss parameter record; all parameters refer to stator side
parameter StrayLoadParametersstrayLoadParametersStray load losses
parameter InductanceLmStator main field inductance per phase
parameter InductanceLrsigmaRotor stray inductance per phase w.r.t. rotor side
parameter InductanceLrzeroRotor zero sequence inductance w.r.t. rotor side
parameter ResistanceRrRotor resistance per phase at TRef w.r.t. rotor side
parameter TemperatureTrRefReference temperature of rotor resistance
parameter LinearTemperatureCoefficient20alpha20rTemperature coefficient of rotor resistance at 20 degC
parameter BooleanuseTurnsRatioUse turnsRatio or calculate from locked-rotor voltage?
parameter RealturnsRatioEffective number of stator turns / effective number of rotor turns
parameter VoltageVsNominalNominal stator voltage per phase
parameter VoltageVrLockedRotorLocked-rotor voltage per phase
parameter CoreParametersrotorCoreParametersRotor core loss parameter record; all parameters refer to rotor side

Record Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​SM_PermanentMagnetData
Common parameters for synchronous induction machines with permanent magnet

Information

Basic parameters of synchronous induction machines with permanent magnet are predefined with default values.

Extends from Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​SM_ReluctanceRotorData (Common parameters for synchronous induction machines with reluctance rotor).

Fields

TypeNameDescription
parameter IntegermNumber of phases
parameter InertiaJrRotor's moment of inertia
parameter InertiaJsStator's moment of inertia
parameter IntegerpNumber of pole pairs (Integer)
parameter FrequencyfsNominalNominal frequency
parameter ResistanceRsStator resistance per phase at TRef
parameter TemperatureTsRefReference temperature of stator resistance
parameter LinearTemperatureCoefficient20alpha20sTemperature coefficient of stator resistance at 20 degC
parameter RealeffectiveStatorTurnsEffective number of stator turns
parameter InductanceLszeroStator zero sequence inductance
parameter InductanceLssigmaStator stray inductance per phase
parameter FrictionParametersfrictionParametersFriction loss parameter record
parameter CoreParametersstatorCoreParametersStator core loss parameter record; all parameters refer to stator side
parameter StrayLoadParametersstrayLoadParametersStray load losses
parameter InductanceLmdStator main field inductance per phase in d-axis
parameter InductanceLmqStator main field inductance per phase in q-axis
parameter BooleanuseDamperCageEnable / disable damper cage
parameter InductanceLrsigmadDamper stray inductance in d-axis
parameter InductanceLrsigmaqDamper stray inductance in q-axis
parameter ResistanceRrdDamper resistance in d-axis at TRef
parameter ResistanceRrqDamper resistance in q-axis at TRef
parameter TemperatureTrRefReference temperature of damper resistances in d- and q-axis
parameter LinearTemperatureCoefficient20alpha20rTemperature coefficient of damper resistances in d- and q-axis
parameter VoltageVsOpenCircuitOpen circuit RMS voltage per phase @ fsNominal
parameter PermanentMagnetLossParameterspermanentMagnetLossParametersPermanent magnet loss parameter record

Record Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​SM_ElectricalExcitedData
Common parameters for synchronous induction machines with electrical excitation

Information

Basic parameters of synchronous induction machines with electrical excitation are predefined with default values.

Extends from Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​SM_ReluctanceRotorData (Common parameters for synchronous induction machines with reluctance rotor).

Fields

TypeNameDescription
parameter IntegermNumber of phases
parameter InertiaJrRotor's moment of inertia
parameter InertiaJsStator's moment of inertia
parameter IntegerpNumber of pole pairs (Integer)
parameter FrequencyfsNominalNominal frequency
parameter ResistanceRsStator resistance per phase at TRef
parameter TemperatureTsRefReference temperature of stator resistance
parameter LinearTemperatureCoefficient20alpha20sTemperature coefficient of stator resistance at 20 degC
parameter RealeffectiveStatorTurnsEffective number of stator turns
parameter InductanceLszeroStator zero sequence inductance
parameter InductanceLssigmaStator stray inductance per phase
parameter FrictionParametersfrictionParametersFriction loss parameter record
parameter CoreParametersstatorCoreParametersStator core loss parameter record; all parameters refer to stator side
parameter StrayLoadParametersstrayLoadParametersStray load losses
parameter InductanceLmdStator main field inductance per phase in d-axis
parameter InductanceLmqStator main field inductance per phase in q-axis
parameter BooleanuseDamperCageEnable / disable damper cage
parameter InductanceLrsigmadDamper stray inductance in d-axis
parameter InductanceLrsigmaqDamper stray inductance in q-axis
parameter ResistanceRrdDamper resistance in d-axis at TRef
parameter ResistanceRrqDamper resistance in q-axis at TRef
parameter TemperatureTrRefReference temperature of damper resistances in d- and q-axis
parameter LinearTemperatureCoefficient20alpha20rTemperature coefficient of damper resistances in d- and q-axis
parameter VoltageVsNominalNominal stator RMS voltage per phase
parameter CurrentIeOpenCircuitOpen circuit excitation current @ nominal voltage and frequency
parameter ResistanceReExcitation resistance at TRef
parameter TemperatureTeRefReference temperature of excitation resistance
parameter LinearTemperatureCoefficient20alpha20eTemperature coefficient of excitation resistance
parameter RealsigmaeStray fraction of total excitation inductance
parameter BrushParametersbrushParametersBrush loss parameter record

Record Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​SM_ReluctanceRotorData
Common parameters for synchronous induction machines with reluctance rotor

Information

Basic parameters of synchronous induction machines with reluctance rotor are predefined with default values.

Extends from Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​InductionMachineData (Common parameters for induction machines).

Fields

TypeNameDescription
parameter IntegermNumber of phases
parameter InertiaJrRotor's moment of inertia
parameter InertiaJsStator's moment of inertia
parameter IntegerpNumber of pole pairs (Integer)
parameter FrequencyfsNominalNominal frequency
parameter ResistanceRsStator resistance per phase at TRef
parameter TemperatureTsRefReference temperature of stator resistance
parameter LinearTemperatureCoefficient20alpha20sTemperature coefficient of stator resistance at 20 degC
parameter RealeffectiveStatorTurnsEffective number of stator turns
parameter InductanceLszeroStator zero sequence inductance
parameter InductanceLssigmaStator stray inductance per phase
parameter FrictionParametersfrictionParametersFriction loss parameter record
parameter CoreParametersstatorCoreParametersStator core loss parameter record; all parameters refer to stator side
parameter StrayLoadParametersstrayLoadParametersStray load losses
parameter InductanceLmdStator main field inductance per phase in d-axis
parameter InductanceLmqStator main field inductance per phase in q-axis
parameter BooleanuseDamperCageEnable / disable damper cage
parameter InductanceLrsigmadDamper stray inductance in d-axis
parameter InductanceLrsigmaqDamper stray inductance in q-axis
parameter ResistanceRrdDamper resistance in d-axis at TRef
parameter ResistanceRrqDamper resistance in q-axis at TRef
parameter TemperatureTrRefReference temperature of damper resistances in d- and q-axis
parameter LinearTemperatureCoefficient20alpha20rTemperature coefficient of damper resistances in d- and q-axis

Record Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​DcPermanentMagnetData
Common parameters for DC machines

Information

Basic parameters of DC machines are predefined with default values.

Extends from Modelica.​Icons.​Record (Icon for records).

Fields

TypeNameDescription
parameter InertiaJrRotor's moment of inertia
parameter InertiaJsStator's moment of inertia
parameter VoltageVaNominalNominal armature voltage
parameter CurrentIaNominalNominal armature current (>0..Motor, <0..Generator)
parameter AngularVelocitywNominalNominal speed
parameter TemperatureTaNominalNominal armature temperature
parameter ResistanceRaArmature resistance at TRef
parameter TemperatureTaRefReference temperature of armature resistance
parameter LinearTemperatureCoefficient20alpha20aTemperature coefficient of armature resistance
parameter InductanceLaArmature inductance
parameter FrictionParametersfrictionParametersFriction loss parameter record
parameter VoltageViNominal 
parameter CoreParameterscoreParametersArmature core loss parameter record
parameter StrayLoadParametersstrayLoadParametersStray load losses
parameter BrushParametersbrushParametersBrush loss parameter record

Record Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​DcElectricalExcitedData
Common parameters for DC machines

Information

Basic parameters of DC machines are predefined with default values.

Extends from Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​DcPermanentMagnetData (Common parameters for DC machines).

Fields

TypeNameDescription
parameter InertiaJrRotor's moment of inertia
parameter InertiaJsStator's moment of inertia
parameter VoltageVaNominalNominal armature voltage
parameter CurrentIaNominalNominal armature current (>0..Motor, <0..Generator)
parameter AngularVelocitywNominalNominal speed
parameter TemperatureTaNominalNominal armature temperature
parameter ResistanceRaArmature resistance at TRef
parameter TemperatureTaRefReference temperature of armature resistance
parameter LinearTemperatureCoefficient20alpha20aTemperature coefficient of armature resistance
parameter InductanceLaArmature inductance
parameter FrictionParametersfrictionParametersFriction loss parameter record
parameter VoltageViNominal 
parameter CoreParameterscoreParametersArmature core loss parameter record
parameter StrayLoadParametersstrayLoadParametersStray load losses
parameter BrushParametersbrushParametersBrush loss parameter record
parameter CurrentIeNominalNominal excitation current
parameter ResistanceReField excitation resistance at TRef
parameter TemperatureTeRefReference temperature of excitation resistance
parameter LinearTemperatureCoefficient20alpha20eTemperature coefficient of excitation resistance
parameter InductanceLeTotal field excitation inductance
parameter RealsigmaeStray fraction of total excitation inductance

Record Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​DcSeriesExcitedData
Common parameters for DC machines

Information

Basic parameters of DC machines are predefined with default values.

Extends from Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​DcPermanentMagnetData (Common parameters for DC machines).

Fields

TypeNameDescription
parameter InertiaJrRotor's moment of inertia
parameter InertiaJsStator's moment of inertia
parameter VoltageVaNominalNominal armature voltage
parameter CurrentIaNominalNominal armature current (>0..Motor, <0..Generator)
parameter AngularVelocitywNominalNominal speed
parameter TemperatureTaNominalNominal armature temperature
parameter ResistanceRaArmature resistance at TRef
parameter TemperatureTaRefReference temperature of armature resistance
parameter LinearTemperatureCoefficient20alpha20aTemperature coefficient of armature resistance
parameter InductanceLaArmature inductance
parameter FrictionParametersfrictionParametersFriction loss parameter record
parameter VoltageViNominal 
parameter CoreParameterscoreParametersArmature core loss parameter record
parameter StrayLoadParametersstrayLoadParametersStray load losses
parameter BrushParametersbrushParametersBrush loss parameter record
parameter ResistanceReSeries excitation resistance at TRef
parameter TemperatureTeRefReference temperature of excitation resistance
parameter LinearTemperatureCoefficient20alpha20eTemperature coefficient of excitation resistance
parameter InductanceLeTotal field excitation inductance
parameter RealsigmaeStray fraction of total excitation inductance
parameter TemperatureTeNominalNominal series excitation temperature

Record Modelica.​Electrical.​Machines.​Utilities.​ParameterRecords.​TransformerData
Common parameters for transformers

Information

Basic parameters of transformers are predefined with default values.

Note: ratio n is defined between primary / secondary line-to-line voltage; therefore the user has to take into account primary and secondary connection!

Extends from Modelica.​Icons.​Record (Icon for records).

Fields

TypeNameDescription
parameter Realn_phaseRatio primary voltage per phase / secondary voltage per phase
parameter StringC1Choose primary connection
parameter StringC2Choose secondary connection
parameter RealnRatio primary voltage (line-to-line) / secondary voltage (line-to-line)
parameter ResistanceR1Primary resistance per phase at TRef
parameter TemperatureT1RefReference temperature of primary resistance
parameter LinearTemperatureCoefficient20alpha20_1Temperature coefficient of primary resistance at 20 degC
parameter InductanceL1sigmaPrimary stray inductance per phase
parameter ResistanceR2Secondary resistance per phase at TRef
parameter TemperatureT2RefReference temperature of secondary resistance
parameter LinearTemperatureCoefficient20alpha20_2Temperature coefficient of secondary resistance at 20 degC
parameter InductanceL2sigmaSecondary stray inductance per phase

Generated 2018-12-12 12:10:15 EST by MapleSim.