Package Modelica.​Electrical.​QuasiStationary.​Machines.​Interfaces
SpacePhasor connector and PartialMachines

Information

This package contains the quasi stationary space phasor connector and partial models for quasi stationary machine models.

Extends from Modelica.​Icons.​InterfacesPackage (Icon for packages containing interfaces).

Package Contents

NameDescription
PartialBasicTransformerPartial model of three-phase transformer

Partial Model Modelica.​Electrical.​QuasiStationary.​Machines.​Interfaces.​PartialBasicTransformer
Partial model of three-phase transformer

Information

Partial model of a three-phase transformer, containing primary and secondary resistances and stray inductances, as well as the iron core. Circuit layout (vector group) of primary and secondary windings have to be defined.
Default values for transformer's parameters (a realistic example) are:
turns ratio n 1
nominal frequency fNominal 50Hz
nominal voltage per phase 100V RMS
nominal current per phase 100A RMS
nominal apparent power 30kVA
primary resistance R1 0.005Ohm per phase at reference temperature
reference temperature T1Ref 20°C
temperature coefficient alpha20_1 01/K
primary stray inductance L1sigma 78E-6H per phase
secondary resistance R2 0.005Ohm per phase at reference temperature
reference temperature T2Ref 20°C
temperature coefficient alpha20_2 01/K
secondary stray inductance L2sigma 78E-6H per phase
operational temperature T1Operational 20°C
operational temperature T2Operational 20°C
These values give the operational parameters:
nominal voltage drop 0.05p.u.
nominal copper losses 300W

Extends from Modelica.​Electrical.​Machines.​Icons.​QuasiStationaryTransformer.

Parameters

TypeNameDefaultDescription
Realn Ratio primary voltage (line-to-line) / secondary voltage (line-to-line)
ResistanceR1 Primary resistance per phase at TRef
TemperatureT1Ref Reference temperature of primary resistance
LinearTemperatureCoefficient20alpha20_1 Temperature coefficient of primary resistance at 20 degC
InductanceL1sigma Primary stray inductance per phase
ResistanceR2 Secondary resistance per phase at TRef
TemperatureT2Ref Reference temperature of secondary resistance
LinearTemperatureCoefficient20alpha20_2 Temperature coefficient of secondary resistance at 20 degC
InductanceL2sigma Secondary stray inductance per phase
BooleanuseThermalPortfalseEnable / disable (=fixed temperatures) thermal port
TemperatureT1Operational Operational temperature of primary resistance
TemperatureT2Operational Operational temperature of secondary resistance

Connectors

TypeNameDescription
PositivePlugplug1Primary plug
NegativePlugplug2Secondary plug
ThermalPortTransformerthermalPort 

Generated 2018-12-12 12:10:31 EST by MapleSim.