SquirrelCage

Squirrel Cage

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

Model of a squirrel cage / symmetrical damper cage in two axis.

The squirrel cage has an optional (conditional) HeatPort, which can be enabled or disabled by the Boolean parameter useHeatPort. Temperatures of both axis are the same, both losses are added. Material properties alpha of both axis are the same.

Parameters (6)

useHeatPort

Value: false

Type: Boolean

Description: =true, if heatPort is enabled

T

Value: T_ref

Type: Temperature (K)

Description: Fixed device temperature if useHeatPort = false

Lrsigma

Value:

Type: Inductance (H)

Description: Rotor stray inductance per phase translated to stator

Rr

Value:

Type: Resistance (Ω)

Description: Rotor resistance per phase translated to stator at T_ref

T_ref

Value: 293.15

Type: Temperature (K)

Description: Reference temperature

alpha

Value: 0

Type: LinearTemperatureCoefficient (¹/K)

Description: Temperature coefficient of resistance at T_ref

Connectors (3)

heatPort

Type: HeatPort_a

Description: Conditional heat port

spacePhasor_r

Type: SpacePhasor

i

Type: RealOutput[2]

Description: Currents out from squirrel cage

Used in Components (1)

AIM_SquirrelCage

Modelica.Electrical.Machines.BasicMachines.AsynchronousInductionMachines

Asynchronous induction machine with squirrel cage rotor