DCEE_Start

Test example: DC with electrical excitation starting with voltage ramp

Diagram

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

Test example: Electrically separate excited DC machine started with an armature voltage ramp
A voltage ramp is applied to the armature, causing the DC machine to start, and accelerating inertias.
At time tStep a load step is applied.
Simulate for 2 seconds and plot (versus time):
  • dcee.ia: armature current
  • dcee.wMechanical: motor's speed
  • dcee.tauElectrical: motor's torque
  • dcee.ie: excitation current
Default machine parameters of model DC_ElectricalExcited are used.

Parameters (8)

Va

Value: 100

Type: Voltage (V)

Description: Actual armature voltage

tStart

Value: 0.2

Type: Time (s)

Description: Start of armature voltage ramp

tRamp

Value: 0.8

Type: Time (s)

Description: Armature voltage ramp

Ve

Value: 100

Type: Voltage (V)

Description: Actual excitation voltage

TLoad

Value: 63.66

Type: Torque (N·m)

Description: Nominal load torque

tStep

Value: 1.5

Type: Time (s)

Description: Time of load torque step

JLoad

Value: 0.15

Type: Inertia (kg·m²)

Description: Load's moment of inertia

dceeData

Value:

Type: DcElectricalExcitedData

Components (9)

dcee

Type: DC_ElectricalExcited

ramp

Type: Ramp

signalVoltage

Type: SignalVoltage

ground

Type: Ground

constantVoltage

Type: ConstantVoltage

groundExcitation

Type: Ground

loadInertia

Type: Inertia

loadTorqueStep

Type: TorqueStep

dceeData

Type: DcElectricalExcitedData