DCEE_StartTest example: DC with electrical excitation starting with voltage ramp |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Test example: Electrically separate excited DC machine started with an armature voltage rampVa |
Value: 100 Type: Voltage (V) Description: Actual armature voltage |
---|---|
tStart |
Value: 0.2 Type: Time (s) Description: Start of armature voltage ramp |
tRamp |
Value: 0.8 Type: Time (s) Description: Armature voltage ramp |
Ve |
Value: 100 Type: Voltage (V) Description: Actual excitation voltage |
TLoad |
Value: 63.66 Type: Torque (N·m) Description: Nominal load torque |
tStep |
Value: 1.5 Type: Time (s) Description: Time of load torque step |
JLoad |
Value: 0.15 Type: Inertia (kg·m²) Description: Load's moment of inertia |
dceeData |
Value: Type: DcElectricalExcitedData |
dcee |
Type: DC_ElectricalExcited |
|
---|---|---|
ramp |
Type: Ramp |
|
signalVoltage |
Type: SignalVoltage |
|
ground |
Type: Ground |
|
constantVoltage |
Type: ConstantVoltage |
|
groundExcitation |
Type: Ground |
|
loadInertia |
Type: Inertia |
|
loadTorqueStep |
Type: TorqueStep |
|
dceeData |
Type: DcElectricalExcitedData |