HallSensorHall sensor |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Simple model of a hall sensor, i.e. measuring the angle of the flange (w.r.t. the optional support), multiplying by the number of phases p to obtain the electrical angle, and adding a correction term i.e. the initial angle of the flange phi0.
Note that phi0 has to be set that way, that in shaft position phi0 the flux linkage of phase 1 is a maximum.
useSupport |
Value: false Type: Boolean Description: = true, if support flange enabled, otherwise implicitly grounded |
---|---|
p |
Value: Type: Integer Description: Number of pole pairs |
phi0 |
Value: -pi / p Type: Angle (rad) Description: Initial mechanical angle |
flange |
Type: Flange_b Description: Flange of shaft |
|
---|---|---|
support |
Type: Support Description: Support/housing of component |
|
y |
Type: RealOutput Description: "Electrical angle" |
Modelica.Electrical.Machines.Examples.SynchronousInductionMachines SMPM at no-load |