RampedRheostatRheostat with linearly decreasing resistance |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Ramped rheostat, used for starting asynchronous induction motors with slipring rotor:
The external rotor resistance RStart
is reduced to zero,
starting at time tStart
with a linear ramp tRamp
.
RStart |
Value: Type: Resistance (Ω) Description: Starting resistance |
---|---|
tStart |
Value: Type: Time (s) Description: Time instance of reducing the rheostat |
tRamp |
Value: Type: Time (s) Description: Duration of ramp |
plug_p |
Type: PositivePlug Description: To positive rotor plug |
|
---|---|---|
plug_n |
Type: NegativePlug Description: To negative rotor plug |
star |
Type: Star |
|
---|---|---|
ground |
Type: Ground |
|
rheostat |
Type: VariableResistor |
|
ramp |
Type: Ramp[m] |