ElectroMagneticConverterWithLeakageInductance

Electro-magnetic energy conversion with a leakage inductance

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

Same as ElectroMagneticConverter with an additional leakage path on the magnetic side (leakage inductance, leakage flux). This model may improve stability especially when the magnetic circuit contains more than one electro-magnetic converter.

Parameters (5)

N

Value:

Type: Real

Description: Number of turns

L

Value: 10e-3

Type: Length (m)

Description: Length in direction of flux

A

Value: 10e-6

Type: Area (m²)

Description: Area of cross-section

mu_rel

Value: 1

Type: RelativePermeability

Description: Constant relative permeability of leakage inductance (> 0 required)

G_m

Value: Modelica.Constants.mue_0 * mu_rel * A / L

Type: Permeance (H)

Description: Magnetic permeance of leakage inductance

Connectors (4)

port_p

Type: PositiveMagneticPort

Description: Positive magnetic port

port_n

Type: NegativeMagneticPort

Description: Negative magnetic port

p

Type: PositivePin

Description: Positive electrical pin

n

Type: NegativePin

Description: Negative electrical pin

Used in Examples (3)

HysteresisModelComparison

Modelica.Magnetic.FluxTubes.Examples.Hysteresis

Comparison of the different hysteresis models

InductorWithHysteresis

Modelica.Magnetic.FluxTubes.Examples.Hysteresis

SinglePhaseTransformerWithHysteresis1

Modelica.Magnetic.FluxTubes.Examples.Hysteresis

Used in Components (2)

Transformer1PhaseWithHysteresis

Modelica.Magnetic.FluxTubes.Examples.Hysteresis.Components

Single Phase transformer with ferromagnetic core and hysteresis

Transformer3PhaseYyWithHysteresis

Modelica.Magnetic.FluxTubes.Examples.Hysteresis.Components

Three phase transformer in Yy configuration