AIMC_Initialize

Steady-state initialization of asynchronous induction machine with squirrel cage

Diagram

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

The asynchronous induction machine with squirrel cage is initialized in steady-state at no-load; at time tStart a load torque step is applied.

Simulate for 1.5 seconds and plot (versus time):

  • currentQuasiRMSSensor.I: stator current RMS
  • aimc.wMechanical: motor's speed
  • aimc.tauElectrical: motor's torque

Default machine parameters are used.

Parameters (8)

VNominal

Value: 100

Type: Voltage (V)

Description: Nominal RMS voltage per phase

fNominal

Value: aimcData.fsNominal

Type: Frequency (Hz)

Description: Nominal frequency

wSync

Value: 2 * pi * fNominal / aimc.p

Type: AngularVelocity (rad/s)

tStart

Value: 0.5

Type: Time (s)

Description: Start time

TLoad

Value: 161.4

Type: Torque (N·m)

Description: Nominal load torque

wLoad

Value: 1440.45 * 2 * Modelica.Constants.pi / 60

Type: AngularVelocity (rad/s)

Description: Nominal load speed

JLoad

Value: 0.29

Type: Inertia (kg·m²)

Description: Load's moment of inertia

aimcData

Value:

Type: AIM_SquirrelCageData

Components (9)

aimc

Type: AIM_SquirrelCage

currentQuasiRMSSensor

Type: CurrentQuasiRMSSensor

sineVoltage

Type: SineVoltage

star

Type: Star

ground

Type: Ground

loadInertia

Type: Inertia

torqueStep

Type: TorqueStep

terminalBox

Type: TerminalBox

aimcData

Type: AIM_SquirrelCageData