AIMC_InitializeSteady-state initialization of asynchronous induction machine with squirrel cage |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
The asynchronous induction machine with squirrel cage is initialized in steady-state at no-load; at time tStart a load torque step is applied.
Simulate for 1.5 seconds and plot (versus time):
Default machine parameters are used.
VNominal |
Value: 100 Type: Voltage (V) Description: Nominal RMS voltage per phase |
---|---|
fNominal |
Value: aimcData.fsNominal Type: Frequency (Hz) Description: Nominal frequency |
wSync |
Value: 2 * pi * fNominal / aimc.p Type: AngularVelocity (rad/s) |
tStart |
Value: 0.5 Type: Time (s) Description: Start time |
TLoad |
Value: 161.4 Type: Torque (N·m) Description: Nominal load torque |
wLoad |
Value: 1440.45 * 2 * Modelica.Constants.pi / 60 Type: AngularVelocity (rad/s) Description: Nominal load speed |
JLoad |
Value: 0.29 Type: Inertia (kg·m²) Description: Load's moment of inertia |
aimcData |
Value: Type: AIM_SquirrelCageData |
aimc |
Type: AIM_SquirrelCage |
|
---|---|---|
currentQuasiRMSSensor |
Type: CurrentQuasiRMSSensor |
|
sineVoltage |
Type: SineVoltage |
|
star |
Type: Star |
|
ground |
Type: Ground |
|
loadInertia |
Type: Inertia |
|
torqueStep |
Type: TorqueStep |
|
terminalBox |
Type: TerminalBox |
|
aimcData |
Type: AIM_SquirrelCageData |