ControlledTemperatureControl temperature of a resistor |
![]() |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
A constant voltage of 10 V is applied to a temperature dependent resistor of 10*(1+(T-20C)/(235+20C)) Ohms, whose losses v**2/r are dissipated via a thermal conductance of 0.1 W/K to ambient temperature 20 degree C. The resistor is assumed to have a thermal capacity of 1 J/K, having ambient temperature at the beginning of the experiment. The temperature of this heating resistor is held by an OnOff-controller at reference temperature within a given bandwidth +/- 1 K by switching on and off the voltage source. The reference temperature starts at 25 degree C and rises between t = 2 and 8 seconds linear to 50 degree C. An appropriate simulating time would be 10 seconds.
TAmb |
Value: 293.15 Type: Temperature (K) Description: Ambient Temperature |
---|---|
TDif |
Value: 2 Type: TemperatureDifference (K) Description: Error in Temperature |
TRes |
Default Value: heatingResistor.T_heatPort Type: Temperature (K) Description: Resulting Temperature |
---|
![]() |
ground |
Type: Ground |
---|---|---|
![]() |
constantVoltage |
Type: ConstantVoltage |
![]() |
heatCapacitor |
Type: HeatCapacitor |
![]() |
heatingResistor |
Type: HeatingResistor |
![]() |
fixedTemperature |
Type: FixedTemperature |
![]() |
temperatureSensor |
Type: TemperatureSensor |
![]() |
thermalConductor |
Type: ThermalConductor |
![]() |
idealSwitch |
Type: IdealOpeningSwitch |
![]() |
ramp |
Type: Ramp |
![]() |
onOffController |
Type: OnOffController |
![]() |
logicalNot |
Type: Not |