Modelica.Electrical.Machines.Utilities.ParameterRecords

Parameter records

Information

Extends from Modelica.Icons.RecordsPackage (Icon for package containing records).

Package Content

Name Description
Modelica.Electrical.Machines.Utilities.ParameterRecords.InductionMachineData InductionMachineData Common parameters for induction machines
Modelica.Electrical.Machines.Utilities.ParameterRecords.IM_SquirrelCageData IM_SquirrelCageData Common parameters for induction machines with squirrel cage
Modelica.Electrical.Machines.Utilities.ParameterRecords.IM_SlipRingData IM_SlipRingData Common parameters for induction machines with slip ring
Modelica.Electrical.Machines.Utilities.ParameterRecords.SM_PermanentMagnetData SM_PermanentMagnetData Common parameters for synchronous machines with permanent magnet
Modelica.Electrical.Machines.Utilities.ParameterRecords.SM_ElectricalExcitedData SM_ElectricalExcitedData Common parameters for synchronous machines with electrical excitation
Modelica.Electrical.Machines.Utilities.ParameterRecords.SM_ReluctanceRotorData SM_ReluctanceRotorData Common parameters for synchronous machines with reluctance rotor
Modelica.Electrical.Machines.Utilities.ParameterRecords.DcPermanentMagnetData DcPermanentMagnetData Common parameters for DC machines
Modelica.Electrical.Machines.Utilities.ParameterRecords.DcElectricalExcitedData DcElectricalExcitedData Common parameters for DC machines
Modelica.Electrical.Machines.Utilities.ParameterRecords.DcSeriesExcitedData DcSeriesExcitedData Common parameters for DC machines
Modelica.Electrical.Machines.Utilities.ParameterRecords.TransformerData TransformerData Common parameters for transformers

Modelica.Electrical.Machines.Utilities.ParameterRecords.InductionMachineData Modelica.Electrical.Machines.Utilities.ParameterRecords.InductionMachineData

Common parameters for induction machines

Information

Basic parameters of induction machines are predefined with default values.

Extends from Modelica.Icons.Record (Icon for records).

Parameters

NameDescription
JrRotor's moment of inertia [kg.m2]
JsStator's moment of inertia [kg.m2]
pNumber of pole pairs (Integer)
fsNominalNominal frequency [Hz]
effectiveStatorTurnsEffective number of stator turns
Nominal resistances and inductances
RsStator resistance per phase at TRef [Ohm]
TsRefReference temperature of stator resistance [K]
alpha20sTemperature coefficient of stator resistance at 20 degC [1/K]
LszeroStator zero sequence inductance [H]
LssigmaStator stray inductance per phase [H]
Losses
frictionParametersFriction loss parameter record
statorCoreParametersStator core loss parameter record; all parameters refer to stator side
strayLoadParametersStray load losses

Modelica.Electrical.Machines.Utilities.ParameterRecords.IM_SquirrelCageData Modelica.Electrical.Machines.Utilities.ParameterRecords.IM_SquirrelCageData

Common parameters for induction machines with squirrel cage

Information

Basic parameters of induction machines with squirrel cage are predefined with default values.

Extends from InductionMachineData (Common parameters for induction machines).

Parameters

NameDescription
JrRotor's moment of inertia [kg.m2]
JsStator's moment of inertia [kg.m2]
pNumber of pole pairs (Integer)
fsNominalNominal frequency [Hz]
effectiveStatorTurnsEffective number of stator turns
Nominal resistances and inductances
RsStator resistance per phase at TRef [Ohm]
TsRefReference temperature of stator resistance [K]
alpha20sTemperature coefficient of stator resistance at 20 degC [1/K]
LszeroStator zero sequence inductance [H]
LssigmaStator stray inductance per phase [H]
LmStator main field inductance per phase [H]
LrsigmaRotor stray inductance per phase (equivalent three-phase winding) [H]
RrRotor resistance per phase (equivalent three-phase winding) at TRef [Ohm]
TrRefReference temperature of rotor resistance [K]
alpha20rTemperature coefficient of rotor resistance at 20 degC [1/K]
Losses
frictionParametersFriction loss parameter record
statorCoreParametersStator core loss parameter record; all parameters refer to stator side
strayLoadParametersStray load losses

Modelica.Electrical.Machines.Utilities.ParameterRecords.IM_SlipRingData Modelica.Electrical.Machines.Utilities.ParameterRecords.IM_SlipRingData

Common parameters for induction machines with slip ring

Information

Basic parameters of induction machines with slip ring are predefined with default values.

Extends from InductionMachineData (Common parameters for induction machines).

Parameters

NameDescription
JrRotor's moment of inertia [kg.m2]
JsStator's moment of inertia [kg.m2]
pNumber of pole pairs (Integer)
fsNominalNominal frequency [Hz]
effectiveStatorTurnsEffective number of stator turns
useTurnsRatioUse turnsRatio or calculate from locked-rotor voltage?
turnsRatioEffective number of stator turns / effective number of rotor turns
VsNominalNominal stator voltage per phase [V]
VrLockedRotorLocked-rotor voltage per phase [V]
Nominal resistances and inductances
RsStator resistance per phase at TRef [Ohm]
TsRefReference temperature of stator resistance [K]
alpha20sTemperature coefficient of stator resistance at 20 degC [1/K]
LszeroStator zero sequence inductance [H]
LssigmaStator stray inductance per phase [H]
LmStator main field inductance per phase [H]
LrsigmaRotor stray inductance per phase w.r.t. rotor side [H]
LrzeroRotor zero sequence inductance w.r.t. rotor side [H]
RrRotor resistance per phase at TRef w.r.t. rotor side [Ohm]
TrRefReference temperature of rotor resistance [K]
alpha20rTemperature coefficient of rotor resistance at 20 degC [1/K]
Losses
frictionParametersFriction loss parameter record
statorCoreParametersStator core loss parameter record; all parameters refer to stator side
strayLoadParametersStray load losses
rotorCoreParametersRotor core loss parameter record; all parameters refer to rotor side

Modelica.Electrical.Machines.Utilities.ParameterRecords.SM_PermanentMagnetData Modelica.Electrical.Machines.Utilities.ParameterRecords.SM_PermanentMagnetData

Common parameters for synchronous machines with permanent magnet

Information

Basic parameters of synchronous machines with permanent magnet are predefined with default values.

Extends from SM_ReluctanceRotorData (Common parameters for synchronous machines with reluctance rotor).

Parameters

NameDescription
JrRotor's moment of inertia [kg.m2]
JsStator's moment of inertia [kg.m2]
pNumber of pole pairs (Integer)
fsNominalNominal frequency [Hz]
effectiveStatorTurnsEffective number of stator turns
VsOpenCircuitOpen circuit RMS voltage per phase @ fsNominal [V]
Nominal resistances and inductances
RsStator resistance per phase at TRef [Ohm]
TsRefReference temperature of stator resistance [K]
alpha20sTemperature coefficient of stator resistance at 20 degC [1/K]
LszeroStator zero sequence inductance [H]
LssigmaStator stray inductance per phase [H]
LmdStator main field inductance per phase in d-axis [H]
LmqStator main field inductance per phase in q-axis [H]
Damper cage
useDamperCageEnable / disable damper cage
LrsigmadDamper stray inductance in d-axis [H]
LrsigmaqDamper stray inductance in q-axis [H]
RrdDamper resistance in d-axis at TRef [Ohm]
RrqDamper resistance in q-axis at TRef [Ohm]
TrRefReference temperature of damper resistances in d- and q-axis [K]
alpha20rTemperature coefficient of damper resistances in d- and q-axis [1/K]
Losses
frictionParametersFriction loss parameter record
statorCoreParametersStator core loss parameter record; all parameters refer to stator side
strayLoadParametersStray load losses
permanentMagnetLossParametersPermanent magnet loss parameter record

Modelica.Electrical.Machines.Utilities.ParameterRecords.SM_ElectricalExcitedData Modelica.Electrical.Machines.Utilities.ParameterRecords.SM_ElectricalExcitedData

Common parameters for synchronous machines with electrical excitation

Information

Basic parameters of synchronous machines with electrical excitation are predefined with default values.

Extends from SM_ReluctanceRotorData (Common parameters for synchronous machines with reluctance rotor).

Parameters

NameDescription
JrRotor's moment of inertia [kg.m2]
JsStator's moment of inertia [kg.m2]
pNumber of pole pairs (Integer)
fsNominalNominal frequency [Hz]
effectiveStatorTurnsEffective number of stator turns
Nominal resistances and inductances
RsStator resistance per phase at TRef [Ohm]
TsRefReference temperature of stator resistance [K]
alpha20sTemperature coefficient of stator resistance at 20 degC [1/K]
LszeroStator zero sequence inductance [H]
LssigmaStator stray inductance per phase [H]
LmdStator main field inductance per phase in d-axis [H]
LmqStator main field inductance per phase in q-axis [H]
Damper cage
useDamperCageEnable / disable damper cage
LrsigmadDamper stray inductance in d-axis [H]
LrsigmaqDamper stray inductance in q-axis [H]
RrdDamper resistance in d-axis at TRef [Ohm]
RrqDamper resistance in q-axis at TRef [Ohm]
TrRefReference temperature of damper resistances in d- and q-axis [K]
alpha20rTemperature coefficient of damper resistances in d- and q-axis [1/K]
Losses
frictionParametersFriction loss parameter record
statorCoreParametersStator core loss parameter record; all parameters refer to stator side
strayLoadParametersStray load losses
brushParametersBrush loss parameter record
Excitation
VsNominalNominal stator RMS voltage per phase [V]
IeOpenCircuitOpen circuit excitation current @ nominal voltage and frequency [A]
ReExcitation resistance at TRef [Ohm]
TeRefReference temperature of excitation resistance [K]
alpha20eTemperature coefficient of excitation resistance [1/K]
sigmaeStray fraction of total excitation inductance

Modelica.Electrical.Machines.Utilities.ParameterRecords.SM_ReluctanceRotorData Modelica.Electrical.Machines.Utilities.ParameterRecords.SM_ReluctanceRotorData

Common parameters for synchronous machines with reluctance rotor

Information

Basic parameters of synchronous machines with reluctance rotor are predefined with default values.

Extends from InductionMachineData (Common parameters for induction machines).

Parameters

NameDescription
JrRotor's moment of inertia [kg.m2]
JsStator's moment of inertia [kg.m2]
pNumber of pole pairs (Integer)
fsNominalNominal frequency [Hz]
effectiveStatorTurnsEffective number of stator turns
Nominal resistances and inductances
RsStator resistance per phase at TRef [Ohm]
TsRefReference temperature of stator resistance [K]
alpha20sTemperature coefficient of stator resistance at 20 degC [1/K]
LszeroStator zero sequence inductance [H]
LssigmaStator stray inductance per phase [H]
LmdStator main field inductance per phase in d-axis [H]
LmqStator main field inductance per phase in q-axis [H]
Damper cage
useDamperCageEnable / disable damper cage
LrsigmadDamper stray inductance in d-axis [H]
LrsigmaqDamper stray inductance in q-axis [H]
RrdDamper resistance in d-axis at TRef [Ohm]
RrqDamper resistance in q-axis at TRef [Ohm]
TrRefReference temperature of damper resistances in d- and q-axis [K]
alpha20rTemperature coefficient of damper resistances in d- and q-axis [1/K]
Losses
frictionParametersFriction loss parameter record
statorCoreParametersStator core loss parameter record; all parameters refer to stator side
strayLoadParametersStray load losses

Modelica.Electrical.Machines.Utilities.ParameterRecords.DcPermanentMagnetData Modelica.Electrical.Machines.Utilities.ParameterRecords.DcPermanentMagnetData

Common parameters for DC machines

Information

Basic parameters of DC machines are predefined with default values.

Extends from Modelica.Icons.Record (Icon for records).

Parameters

NameDescription
JrRotor's moment of inertia [kg.m2]
JsStator's moment of inertia [kg.m2]
ViNominalInduced voltage at nominal operating point [V]
Nominal parameters
VaNominalNominal armature voltage [V]
IaNominalNominal armature current (>0..Motor, <0..Generator) [A]
wNominalNominal speed [rad/s]
TaNominalNominal armature temperature [K]
Armature
RaArmature resistance at TaRef [Ohm]
TaRefReference temperature of armature resistance [K]
alpha20aTemperature coefficient of armature resistance [1/K]
LaArmature inductance [H]
Losses
frictionParametersFriction loss parameter record
coreParametersArmature core loss parameter record
strayLoadParametersStray load losses
brushParametersBrush loss parameter record

Modelica.Electrical.Machines.Utilities.ParameterRecords.DcElectricalExcitedData Modelica.Electrical.Machines.Utilities.ParameterRecords.DcElectricalExcitedData

Common parameters for DC machines

Information

Basic parameters of DC machines are predefined with default values.

Extends from DcPermanentMagnetData (Common parameters for DC machines).

Parameters

NameDescription
JrRotor's moment of inertia [kg.m2]
JsStator's moment of inertia [kg.m2]
ViNominalInduced voltage at nominal operating point [V]
Nominal parameters
VaNominalNominal armature voltage [V]
IaNominalNominal armature current (>0..Motor, <0..Generator) [A]
wNominalNominal speed [rad/s]
TaNominalNominal armature temperature [K]
Armature
RaArmature resistance at TaRef [Ohm]
TaRefReference temperature of armature resistance [K]
alpha20aTemperature coefficient of armature resistance [1/K]
LaArmature inductance [H]
Losses
frictionParametersFriction loss parameter record
coreParametersArmature core loss parameter record
strayLoadParametersStray load losses
brushParametersBrush loss parameter record
Excitation
IeNominalNominal excitation current [A]
ReField excitation resistance at TeRef [Ohm]
TeRefReference temperature of excitation resistance [K]
alpha20eTemperature coefficient of excitation resistance [1/K]
LeTotal field excitation inductance [H]
sigmaeStray fraction of total excitation inductance

Modelica.Electrical.Machines.Utilities.ParameterRecords.DcSeriesExcitedData Modelica.Electrical.Machines.Utilities.ParameterRecords.DcSeriesExcitedData

Common parameters for DC machines

Information

Basic parameters of DC machines are predefined with default values.

Extends from DcPermanentMagnetData (Common parameters for DC machines).

Parameters

NameDescription
JrRotor's moment of inertia [kg.m2]
JsStator's moment of inertia [kg.m2]
ViNominalInduced voltage at nominal operating point [V]
Nominal parameters
VaNominalNominal armature voltage [V]
IaNominalNominal armature current (>0..Motor, <0..Generator) [A]
wNominalNominal speed [rad/s]
TaNominalNominal armature temperature [K]
TeNominalNominal series excitation temperature [K]
Armature
RaArmature resistance at TaRef [Ohm]
TaRefReference temperature of armature resistance [K]
alpha20aTemperature coefficient of armature resistance [1/K]
LaArmature inductance [H]
Losses
frictionParametersFriction loss parameter record
coreParametersArmature core loss parameter record
strayLoadParametersStray load losses
brushParametersBrush loss parameter record
Excitation
ReSeries excitation resistance at TeRef [Ohm]
TeRefReference temperature of excitation resistance [K]
alpha20eTemperature coefficient of excitation resistance [1/K]
LeTotal field excitation inductance [H]
sigmaeStray fraction of total excitation inductance

Modelica.Electrical.Machines.Utilities.ParameterRecords.TransformerData Modelica.Electrical.Machines.Utilities.ParameterRecords.TransformerData

Common parameters for transformers

Information

Basic parameters of transformers are predefined with default values.

Note: ratio n is defined between primary / secondary line-to-line voltage; therefore the user has to take into account primary and secondary connection!

Extends from Modelica.Icons.Record (Icon for records).

Parameters

NameDescription
n_phaseRatio primary voltage per phase / secondary voltage per phase
C1Choose primary connection
C2Choose secondary connection
nRatio primary voltage (line-to-line) / secondary voltage (line-to-line)
Nominal resistances and inductances
R1Primary resistance per phase at TRef [Ohm]
T1RefReference temperature of primary resistance [K]
alpha20_1Temperature coefficient of primary resistance at 20 degC [1/K]
L1sigmaPrimary stray inductance per phase [H]
R2Secondary resistance per phase at TRef [Ohm]
T2RefReference temperature of secondary resistance [K]
alpha20_2Temperature coefficient of secondary resistance at 20 degC [1/K]
L2sigmaSecondary stray inductance per phase [H]
Automatically generated Thu Oct 1 16:07:42 2020.