Modelica.Magnetic.FluxTubes.Shapes.Force

Flux tubes with reluctance force generation; constant permeability

Information

Please have a look at UsersGuide.ReluctanceForceCalculation for an explanation of the different flux tube categories and resulting sub-packages.

Flux tube elements with generation of a reluctance force are intended for modelling of position-dependent air gap sections and permanent magnet sections respectively of translatory actuators. By default, the position co-ordinate of the mechanical connector flange.s is identical with the dimension l of the package's flux tube elements. l is the dimension changes with armature motion. If needed, the identity l=flange.s can be replaced by an actuator-specific equation, for example, when a flux tube length increases with decreasing armature position. The position co-ordinate of an element's translatory connector flange.s in turn will be identical with the armature position x in most cases, as the examples illustrate.

The derivative of each element's permeance with respect to armature position dGmBydx is calculated from the derivative of the flux tube's permeance with respect to its varying dimension dGmBydl and the derivative of this dimension with respect to armature position dlBydx:

dG_m   dG_m   dl
---- = ---- * --
 dx     dl    dx

The parameter dlBydx must be set in each flux tube element to +1 or -1 according to the definition of the armature co-ordinate and the position of the element in a device's magnetic circuit. Proper match between armature motion and resulting variation of the flux tube length assures that the element's reluctance force acts in the right direction.

The shapes of the flux tubes defined in this package are rather simple. Only one dimension varies with armature motion. Flux tubes with more complex variations of dimensions with armature motion can be defined by extending the base class BaseClasses.Force, if needed. Determination of the analytic derivative dGmBydl could become more complex for those flux tubes.

Extends from Modelica.Icons.VariantsPackage (Icon for package containing variants).

Package Content

Name Description
Modelica.Magnetic.FluxTubes.Shapes.Force.HollowCylinderAxialFlux HollowCylinderAxialFlux (Hollow) cylinder with axial flux; constant permeability
Modelica.Magnetic.FluxTubes.Shapes.Force.HollowCylinderRadialFlux HollowCylinderRadialFlux Hollow cylinder with radial flux; constant permeability
Modelica.Magnetic.FluxTubes.Shapes.Force.CuboidParallelFlux CuboidParallelFlux Cuboid with flux in direction of motion, e.g., air gap with rectangular cross-section; constant permeability
Modelica.Magnetic.FluxTubes.Shapes.Force.CuboidOrthogonalFlux CuboidOrthogonalFlux Cuboid with flux orthogonal to direction of motion; constant permeability
Modelica.Magnetic.FluxTubes.Shapes.Force.LeakageAroundPoles LeakageAroundPoles Leakage flux tube around cylindrical or prismatic poles

Modelica.Magnetic.FluxTubes.Shapes.Force.HollowCylinderAxialFlux Modelica.Magnetic.FluxTubes.Shapes.Force.HollowCylinderAxialFlux

(Hollow) cylinder with axial flux; constant permeability

Information

Please refer to the enclosing sub-package Force for a description of all elements of this package and to [Ro41] for derivation and/or coefficients of the equation for permeance G_m.

Extends from BaseClasses.Force (Base class for flux tubes with reluctance force generation; constant permeability).

Parameters

NameDescription
useSupport= true, if support flange enabled, otherwise implicitly grounded
mu_rRelative magnetic permeability [1]
dlBydxDerivative of flux tube's varying dimension with respect to armature position; set to +1 or -1
r_iInner radius of (hollow) cylinder [m]
r_oOuter radius of (hollow) cylinder [m]
Initialization
PhiMagnetic flux from port_p to port_n [Wb]
Variable geometry
lAxial length (in direction of flux) [m]

Connectors

NameDescription
port_pPositive magnetic port
port_nNegative magnetic port
flangeGenerated reluctance force at armature position
supportSupport/housing of component

Modelica.Magnetic.FluxTubes.Shapes.Force.HollowCylinderRadialFlux Modelica.Magnetic.FluxTubes.Shapes.Force.HollowCylinderRadialFlux

Hollow cylinder with radial flux; constant permeability

Information

Please refer to the enclosing sub-package Force for a description of all elements of this package and to [Ro41] for derivation and/or coefficients of the equation for permeance G_m.

Extends from BaseClasses.Force (Base class for flux tubes with reluctance force generation; constant permeability).

Parameters

NameDescription
useSupport= true, if support flange enabled, otherwise implicitly grounded
mu_rRelative magnetic permeability [1]
dlBydxDerivative of flux tube's varying dimension with respect to armature position; set to +1 or -1
r_iInner radius of hollow cylinder [m]
r_oOuter radius of hollow cylinder [m]
Initialization
PhiMagnetic flux from port_p to port_n [Wb]
Variable geometry
lAxial length (orthogonal to direction of flux) [m]

Connectors

NameDescription
port_pPositive magnetic port
port_nNegative magnetic port
flangeGenerated reluctance force at armature position
supportSupport/housing of component

Modelica.Magnetic.FluxTubes.Shapes.Force.CuboidParallelFlux Modelica.Magnetic.FluxTubes.Shapes.Force.CuboidParallelFlux

Cuboid with flux in direction of motion, e.g., air gap with rectangular cross-section; constant permeability

Information

Please refer to the enclosing sub-package Force for a description of all elements of this package and to [Ro41] for derivation and/or coefficients of the equation for permeance G_m.

Extends from BaseClasses.Force (Base class for flux tubes with reluctance force generation; constant permeability).

Parameters

NameDescription
useSupport= true, if support flange enabled, otherwise implicitly grounded
mu_rRelative magnetic permeability [1]
dlBydxDerivative of flux tube's varying dimension with respect to armature position; set to +1 or -1
aWidth of rectangular cross-section [m]
bHeight of rectangular cross-section [m]
Initialization
PhiMagnetic flux from port_p to port_n [Wb]
Variable geometry
lAxial length (in direction of flux) [m]

Connectors

NameDescription
port_pPositive magnetic port
port_nNegative magnetic port
flangeGenerated reluctance force at armature position
supportSupport/housing of component

Modelica.Magnetic.FluxTubes.Shapes.Force.CuboidOrthogonalFlux Modelica.Magnetic.FluxTubes.Shapes.Force.CuboidOrthogonalFlux

Cuboid with flux orthogonal to direction of motion; constant permeability

Information

Please refer to the enclosing sub-package Force for a description of all elements of this package and to [Ro41] for derivation and/or coefficients of the equation for permeance G_m.

Extends from BaseClasses.Force (Base class for flux tubes with reluctance force generation; constant permeability).

Parameters

NameDescription
useSupport= true, if support flange enabled, otherwise implicitly grounded
mu_rRelative magnetic permeability [1]
dlBydxDerivative of flux tube's varying dimension with respect to armature position; set to +1 or -1
aWidth of rectangular cross-section [m]
bHeight of rectangular cross-section (in flux direction) [m]
Initialization
PhiMagnetic flux from port_p to port_n [Wb]
Variable geometry
lLength in direction of motion (orthogonal to flux) [m]

Connectors

NameDescription
port_pPositive magnetic port
port_nNegative magnetic port
flangeGenerated reluctance force at armature position
supportSupport/housing of component

Modelica.Magnetic.FluxTubes.Shapes.Force.LeakageAroundPoles Modelica.Magnetic.FluxTubes.Shapes.Force.LeakageAroundPoles

Leakage flux tube around cylindrical or prismatic poles

Information

Please refer to the description of the enclosing sub-package Force for a description of all elements of this package.

Leakage flux around a prismatic or cylindric air gap between to poles can be described with this model. Due to its constant radius of the leakage field r, the model is rather simple. Whereas in reality the leakage radius is approximately constant for air gap lengths l greater than this radius, it decreases with air gap lengths less than the leakage radius. This decrease for small air gaps is neglected here, since the influence of the leakage flux tube compared to that of the enclosed main air gap (connected in parallel) decreases for decreasing air gap length l.

Note that in [Ka08] the equation for G_m is accidentally swapped with that of a similar element.

Extends from BaseClasses.Force (Base class for flux tubes with reluctance force generation; constant permeability).

Parameters

NameDescription
useSupport= true, if support flange enabled, otherwise implicitly grounded
mu_rRelative magnetic permeability [1]
dlBydxDerivative of flux tube's varying dimension with respect to armature position; set to +1 or -1
wWidth orthogonal to flux; mean circumference of flux tube in case of cylindrical poles [m]
rRadius of leakage field [m]
Initialization
PhiMagnetic flux from port_p to port_n [Wb]
Variable geometry
lAxial length (in direction of flux) [m]

Connectors

NameDescription
port_pPositive magnetic port
port_nNegative magnetic port
flangeGenerated reluctance force at armature position
supportSupport/housing of component
Automatically generated Thu Oct 1 16:07:49 2020.