Illustration of component usage with simple models of various devices
This package contains examples to demonstrate the usage of the quasi-static flux tubes components.
Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).
| Name | Description |
|---|---|
| Linear inductor with ferromagnetic core | |
| Non linear inductor with ferromagnetic core | |
| Educational examples | |
| Examples of fixed shape magnetic circuits | |
| Examples of magnetic circuits with leakage |
Modelica.Magnetic.QuasiStatic.FluxTubes.Examples.LinearInductorLinear inductor with ferromagnetic core
This model compares a transient-linear magnetic circuit with a quasi-static magnetic circuit. A sinusoidal voltage is applied to an inductor with a closed ferromagnetic core of rectangular shape.
Compare the following quantities
source.v | sourceQS.v.re|imcurrentSensor.i | currentSensorQS.i.re|imfeedback.yr_mFe.mu_rConst | r_mFeQS.mu_rConstExtends from Modelica.Icons.Example (Icon for runnable examples).
Modelica.Magnetic.QuasiStatic.FluxTubes.Examples.NonLinearInductorNon linear inductor with ferromagnetic core
This model compares a transient non-linear magnetic circuit with a linearized quasi-static magnetic circuit. A sinusoidal voltage is applied to an inductor with a closed ferromagnetic core of rectangular shape.
Compare the following quantities
source.v | sourceQS.v.re|imcurrentSensor.i | currentSensorQS.i.re|imfeedback.yfundamentalWavePermabilitySensor.mur | r_mFeQS.mu_rConstExtends from Modelica.Icons.Example (Icon for runnable examples).
Automatically generated Thu Oct 1 16:07:51 2020.