IdealClosingSwitchIdeal electrical closer |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
The switching behaviour of the ideal closing switch is controlled by the input signal control: off = not control.
For further details, see partial model IdealSwitch.
useHeatPort |
Value: false Type: Boolean Description: = true, if heatPort is enabled |
---|---|
T |
Value: 293.15 Type: Temperature (K) Description: Fixed device temperature if useHeatPort = false |
Ron |
Value: 1e-5 Type: Resistance (Ω) Description: Closed switch resistance |
Goff |
Value: 1e-5 Type: Conductance (S) Description: Opened switch conductance |
p |
Type: PositivePin Description: Positive electrical pin |
|
---|---|---|
n |
Type: NegativePin Description: Negative electrical pin |
|
heatPort |
Type: HeatPort_a Description: Conditional heat port |
|
control |
Type: BooleanInput Description: true => p--n connected, false => switch open |
Modelica.Electrical.Analog.Examples Comparison of switch models both with and without arc |
|
Modelica.Electrical.Machines.Examples.InductionMachines InductionMachineSquirrelCage Steinmetz-connection |
|
Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.InductionMachines Induction machine with squirrel cage and Steinmetz-connection |
Modelica.Electrical.Polyphase.Ideal Polyphase ideal closer |