MultiDeltaDelta (polygon) connection of polyphase systems consisting of multiple base systems  | 
     | 
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Delta (polygon) connection of a polyphase circuit consisting of multiple base systems (see polyphase guidelines).
If kPolygon<1 or kPolygon>(mBasic - 1)/2, kPolygon is replaced by the value 1 without further warning.
In case of m=2, kPolygon=1 is the only valid choice.
| m | 
         Value: 3 Type: Integer Description: Number of phases  | 
    
|---|---|
| kPolygon | 
         Value: 1 Type: Integer Description: Alternative of polygon  | 
    
| mSystems | 
         Value: numberOfSymmetricBaseSystems(m) Type: Integer Description: Number of base systems  | 
    
| mBasic | 
         Value: integer(m / mSystems) Type: Integer Description: Phase number of base systems  | 
    
| plug_p | 
         Type: PositivePlug  | 
    |
|---|---|---|
| plug_n | 
         Type: NegativePlug  | 
    
| 
        