ThyristorCenterTap2mPulse_RL2*m pulse thyristor rectifier with R-L load |
|
This information is part of the Modelica Standard Library maintained by the Modelica Association.
This example shows a controlled 2*m pulse center tap rectifier with R-L load, where m is the number of phases.
Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.
| m |
Value: 3 Type: Integer Description: Number of phases |
|---|---|
| Vrms |
Value: 110 Type: Voltage (V) Description: RMS supply voltage |
| f |
Value: 50 Type: Frequency (Hz) Description: Frequency |
| constantFiringAngle |
Value: 30 * pi / 180 Type: Angle (rad) Description: Firing angle |
| R |
Value: 20 Type: Resistance (Ω) Description: Load resistance |
| L |
Value: 1 Type: Inductance (H) Description: Load resistance |
| ground |
Type: Ground |
|
|---|---|---|
| star |
Type: Star |
|
| sineVoltage_p |
Type: SineVoltage |
|
| rectifier | ||
| voltagesensor |
Type: VoltageSensor |
|
| meanVoltage |
Type: Mean |
|
| rootMeanSquareVoltage |
Type: RootMeanSquare |
|
| currentSensor |
Type: CurrentSensor |
|
| meanCurrent |
Type: Mean |
|
| pulse2m |
Type: VoltageCenterTap2mPulse |
|
| sineVoltage_n |
Type: SineVoltage |
|
| resistor |
Type: Resistor |
|
| inductor |
Type: Inductor |