ThyristorCenterTap2mPulse_RLV

2*m pulse thyristor center tap rectifier with R-L load and voltage

Diagram

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

This example shows a controlled 2*m pulse center tap rectifier with R-L load including DC voltage source, where m is the number of phases. The additional DC voltage source in this example enables negative average load voltages.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Parameters (7)

m

Value: 3

Type: Integer

Description: Number of phases

Vrms

Value: 110

Type: Voltage (V)

Description: RMS supply voltage

f

Value: 50

Type: Frequency (Hz)

Description: Frequency

constantFiringAngle

Value: 30 * pi / 180

Type: Angle (rad)

Description: Firing angle

R

Value: 20

Type: Resistance (Ω)

Description: Load resistance

L

Value: 1

Type: Inductance (H)

Description: Load resistance

VDC

Value: -260

Type: Voltage (V)

Description: DC load offset voltage

Components (14)

ground

Type: Ground

star

Type: Star

sineVoltage_p

Type: SineVoltage

rectifier

Type: ThyristorCenterTap2mPulse

voltagesensor

Type: VoltageSensor

meanVoltage

Type: Mean

rootMeanSquareVoltage

Type: RootMeanSquare

currentSensor

Type: CurrentSensor

meanCurrent

Type: Mean

pulse2m

Type: VoltageCenterTap2mPulse

sineVoltage_n

Type: SineVoltage

resistor

Type: Resistor

inductor

Type: Inductor

constantVoltage

Type: ConstantVoltage