Force

External force acting on a drive train element as input signal

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

The input signal "f" in [N] characterizes an external force which acts (with positive sign) at a flange, i.e., the component connected to the flange is driven by force f.

Input signal f can be provided from one of the signal generator blocks of Modelica.Blocks.Source.

Parameters (1)

useSupport

Value: false

Type: Boolean

Description: = true, if support flange enabled, otherwise implicitly grounded

Connectors (3)

flange

Type: Flange_b

Description: Flange of component

support

Type: Support

Description: Support/housing of component

f

Type: RealInput

Description: Driving force as input signal

Used in Examples (8)

SignConvention

Modelica.Mechanics.Translational.Examples

Examples for the used sign conventions

Oscillator

Modelica.Mechanics.Translational.Examples

Oscillator demonstrates the use of initial conditions

Sensors

Modelica.Mechanics.Translational.Examples

Sensors for translational systems

Friction

Modelica.Mechanics.Translational.Examples

Use of model Stop

PreLoad

Modelica.Mechanics.Translational.Examples

Preload of a spool using ElastoGap models

HeatLosses

Modelica.Mechanics.Translational.Examples

Demonstrate the modeling of heat losses

GenerationOfFMUs

Modelica.Mechanics.Translational.Examples

Example to demonstrate variants to generate FMUs (Functional Mock-up Units)

TestCylinder

Modelica.Thermal.FluidHeatFlow.Examples

Two cylinder system

Used in Components (2)

DirectMass

Modelica.Mechanics.Translational.Examples.Utilities

Input/output block of a direct mass model

Vehicle

Modelica.Mechanics.Translational.Components

Simple vehicle model