Information

Calculation of the mean convective heat transfer coefficient kc of a helical pipe for turbulent flow regime. See more information .

Interface

function kc_turbulent_KC
  extends Modelica.Icons.Function;
  input Modelica.Fluid.Dissipation.HeatTransfer.HelicalPipe.kc_turbulent_IN_con IN_con "Input record for function kc_turbulent_KC" annotation(
    Dialog(group = "Constant inputs"));
  input Modelica.Fluid.Dissipation.HeatTransfer.HelicalPipe.kc_turbulent_IN_var IN_var "Input record for function kc_turbulent_KC" annotation(
    Dialog(group = "Variable inputs"));
  output SI.CoefficientOfHeatTransfer kc "Output for function kc_turbulent_KC";
end kc_turbulent_KC;

Revisions

2016-04-11 Stefan Wischhusen: Removed singularity for Re at zero mass flow rate.