GreaterThreshold

Output y is true, if input u is greater than threshold

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

The output is true if the Real input is greater than parameter threshold, otherwise the output is false.

Parameters (1)

threshold

Value: 0

Type: Real

Description: Comparison with respect to threshold

Connectors (2)

u

Type: RealInput

Description: Connector of Real input signal

y

Type: BooleanOutput

Description: Connector of Boolean output signal

Used in Examples (2)

AIMC_Steinmetz

Modelica.Electrical.Machines.Examples.AsynchronousInductionMachines

AsynchronousInductionMachineSquirrelCage Steinmetz-connection

AIMC_Steinmetz

Modelica.Magnetic.FundamentalWave.Examples.BasicMachines

Asynchronous induction machine with squirrel cage and Steinmetz-connection

Used in Components (2)

TotalHarmonicDistortion

Modelica.Blocks.Math

Output the total harmonic distortion (THD)

Signal2mPulse

Modelica.Electrical.PowerConverters.ACDC.Control

Generic control of 2*m pulse rectifiers