BooleanOutput'output Boolean' as connector |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
Connector with one output signal of type Boolean.
Modelica.Blocks.Continuous Output the integral of the input signal with optional reset |
|
Modelica.Blocks.Continuous Integrator with limited value of the output and optional reset |
|
Modelica.Blocks.Interaction.Show Show Boolean value from numberPort or from number input field in diagram layer dynamically |
|
Modelica.Blocks.Interfaces Single Input Single Output control block with signals of type Boolean |
|
Modelica.Blocks.Interfaces Multiple Input Multiple Output continuous control block with same number of inputs and outputs of Boolean type |
|
Modelica.Blocks.Interfaces 2 Multiple Input / Boolean Multiple Output block with same signal lengths |
|
Modelica.Blocks.Interfaces 2 Single Input / Boolean Single Output block |
|
Modelica.Blocks.Interfaces Base class for Boolean signal sources |
|
Modelica.Blocks.Interfaces Integer Input Boolean Output continuous control block |
|
Modelica.Blocks.Interfaces Multiple Integer Input Multiple Boolean Output continuous control block with same number of inputs and outputs |
|
Modelica.Blocks.Interfaces Partial block with 1 input and 1 output Boolean signal |
|
Modelica.Blocks.Interfaces Partial block with 2 input and 1 output Boolean signal |
|
Modelica.Blocks.Interfaces Partial block with 3 input and 1 output Boolean signal |
|
Modelica.Blocks.Interfaces Partial block with 1 output Boolean signal |
|
Modelica.Blocks.Interfaces Partial source block (has 1 output Boolean signal and an appropriate default icon) |
|
partialBooleanThresholdComparison Modelica.Blocks.Interfaces Partial block to compare the Real input u with a threshold and provide the result as 1 Boolean output signal |
|
Modelica.Blocks.Interfaces Partial block with 2 Real input and 1 Boolean output signal (the result of a comparison of the two Real inputs) |
|
Modelica.Blocks.Interfaces Partial block with a BooleanInput and a BooleanOutput signal and a small block icon |
|
Modelica.Blocks.Interfaces Partial block with a BooleanVectorInput and a BooleanOutput signal |
|
Modelica.Blocks.Interfaces.Adaptors Obsolete block to send Boolean signal to bus |
|
Modelica.Blocks.Interfaces.Adaptors Obsolete block to receive Boolean signal from bus |
|
Modelica.Blocks.Logical Transform Real to Boolean signal with Hysteresis |
|
Modelica.Blocks.Logical On-off controller |
|
Modelica.Blocks.Logical A basic RS Flip Flop |
|
Modelica.Blocks.Logical Terminate simulation if condition is fulfilled |
|
Modelica.Blocks.Math Output the total harmonic distortion (THD) |
|
Modelica.Blocks.Math Determines the hypotenuse or leg of a right triangle |
|
Modelica.Blocks.MathInteger Add input to previous value of output, if rising edge of trigger port |
|
Modelica.Blocks.MathBoolean Set Boolean expression that is associated with the first active input signal |
|
Modelica.Blocks.Routing Boolean signal replicator |
|
Modelica.Blocks.Sources Set output signal to a time varying Boolean expression |
|
Modelica.Blocks.Sources Move as fast as possible from start to end position within given kinematic constraints with output signals q, qd=der(q), qdd=der(qd) |
|
Modelica.Blocks.Sources Boolean signal source that mimics a radio button |
|
Modelica.StateGraph.Examples.Utilities Controller for tank system |
|
Modelica.StateGraph Initial step (= step that is active when simulation starts). Connector 'active' is true when the step is active |
|
Modelica.StateGraph Ordinary step (= step that is not active when simulation starts). Connector 'active' is true when the step is active |
|
Modelica.StateGraph.Temporary Button that sets its output to true when pressed and is reset when an element of 'reset' becomes true |
|
Modelica.Electrical.Digital.Converters Logic to Boolean converter |
|
Modelica.Electrical.PowerConverters.ACDC.Control Generic control of 2*m pulse rectifiers |
|
Modelica.Electrical.PowerConverters.ACDC.Control Control of 2 pulse bridge rectifier |
|
Modelica.Electrical.PowerConverters.ACDC.Control Control of 2*m pulse bridge rectifier |
|
Modelica.Electrical.PowerConverters.ACDC.Control Control of 2*m pulse center tap rectifier |
|
Modelica.Electrical.PowerConverters.DCAC.Control PulseWidthModulation |
|
Modelica.Electrical.PowerConverters.DCAC.Control SpaceVector Pulse Width Modulation |
|
Modelica.Electrical.PowerConverters.DCAC.Control Intersective PWM |
|
Modelica.Electrical.PowerConverters.DCDC.Control Generates a pulse width modulated (PWM) boolean fire signal |
|
Modelica.Electrical.PowerConverters.Enable Partial model providing enable parameter and optional enable input |
|
Modelica.Fluid.Examples.ControlledTankSystem.Utilities Controller for tank system |
|
Modelica.Fluid.Examples.ControlledTankSystem.Utilities Button that sets its output to true when pressed and is reset when an element of 'reset' becomes true |