ThreePhaseTransformerWithRectifier

3 Phase transformer (including hysteresis effect) with rectifier

Diagram

Information

This information is part of the Modelica Standard Library maintained by the Modelica Association.

This is a model of a three-phase transformer and rectifier unit using the Transformer3PhaseYyWithHysteresis model. Use the following simulation settings:

  • Stop time: 0.2 s
  • Number of intervals: 5000
  • Tolerance: 1e-6

An example simulation shows the transformer inrush currents due to an initially magnetized transformer core.

Fig. 1: Transformer inrush currents due to initial magnetization of the magnetic core; (a) transformer primary currents; (b) transformer secondary currents; (c) flux densities of the transformer legs; (d) B(H) hysteresis loops of transformer leg one.; (e) instantaneous static hysteresis, eddy current and copper losses of the transformer; (f) approximated average static hysteresis, eddy current and copper losses of the transformer

Components (27)

ground1

Type: Ground

ground2

Type: Ground

vSource1

Type: SineVoltage

transformer

Type: Transformer3PhaseYyWithHysteresis

vSource2

Type: SineVoltage

vSource3

Type: SineVoltage

resistor1

Type: Resistor

resistor2

Type: Resistor

resistor3

Type: Resistor

diode1

Type: IdealDiode

diode2

Type: IdealDiode

resistorL

Type: Resistor

diode3

Type: IdealDiode

diode4

Type: IdealDiode

diode5

Type: IdealDiode

diode6

Type: IdealDiode

capacitor1

Type: Capacitor

inductor1

Type: Inductor

inductor2

Type: Inductor

inductor3

Type: Inductor

capacitor2

Type: Capacitor

rExp1

Type: RealExpression

rExp2

Type: RealExpression

rExp3

Type: RealExpression

pdissStatAvg

Type: Filter

Description: Approx. average static hysteresis losses

pdissEddyAvg

Type: Filter

Description: Approx. average eddy current losses

pdissCopAvg

Type: Filter

Description: Approx. average copper losses