InductorIdeal linear electrical inductor |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
The linear inductor connects the branch voltage v with the branch current i by v = L * di/dt. The Inductance L is allowed to be positive, or zero.
L |
Value: Type: Inductance (H) Description: Inductance |
---|
p |
Type: PositivePin Description: Positive electrical pin |
|
---|---|---|
n |
Type: NegativePin Description: Negative electrical pin |
Modelica.Electrical.Analog.Examples Cauer low pass filter with analog components |
|
Modelica.Electrical.Analog.Examples Chua's circuit, ns, V, A |
|
Modelica.Electrical.Analog.Examples B6 diode bridge |
|
Modelica.Electrical.Analog.Examples Simple demo to show behaviour of SaturatingInductor component |
|
Modelica.Electrical.Analog.Examples Comparison of switch models both with and without arc |
|
Modelica.Electrical.Analog.Examples Thyristor demonstration example |
|
Modelica.Electrical.Analog.Examples Transformer circuit to show the magnetization facilities |
|
Modelica.Electrical.Analog.Examples Comparison of controlled switch models both with and without arc |
|
Modelica.Electrical.Analog.Examples Simple triac test circuit |
|
Modelica.Electrical.Analog.Examples Example to demonstrate variants to generate FMUs (Functional Mock-up Units) |
|
Modelica.Electrical.Analog.Examples Resonance circuits: example to demonstrate generation of FMUs (Functional Mock-up Units) |
|
Modelica.Electrical.Analog.Examples.OpAmps LC oscillator |
|
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2Pulse Two pulse Graetz thyristor bridge rectifier with R-L load |
|
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2Pulse Two pulse Graetz thyristor bridge rectifier with R-L load and voltage |
|
ThyristorBridge2Pulse_RLV_Characteristic Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2Pulse Characteristic of two pulse Graetz thyristor bridge rectifier with R-L load and voltage |
|
ThyristorBridge2Pulse_DC_Drive Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2Pulse Two pulse Graetz thyristor bridge feeding a DC drive |
|
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse Two pulse thyristor rectifier with center tap and R-L load |
|
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse Two pulse thyristor rectifier with center tap and R-L load and voltage |
|
ThyristorCenterTap2Pulse_RLV_Characteristic Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse Characteristic of two pulse thyristor rectifier with center tap and R-L load and voltage |
|
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTapmPulse 2*m pulse thyristor rectifier with center tap and R-L load |
|
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTapmPulse 2*m pulse thyristor rectifier with center tap and R-L load and voltage |
|
ThyristorCenterTapmPulse_RLV_Characteristic Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTapmPulse Characteristic of 2*m pulse thyristor rectifier with center tap and R-L load and voltage |
|
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2mPulse 2*m pulse thyristor rectifier bridge with R-L load |
|
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2mPulse 2*m pulse thyristor rectifier bridge with R-L load and voltage |
|
ThyristorBridge2mPulse_RLV_Characteristic Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2mPulse Characteristic of 2*m pulse thyristor rectifier bridge with R-L load and voltage |
|
ThyristorBridge2mPulse_DC_Drive Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2mPulse 2*m pulse thyristor bridge feeding a DC drive |
|
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse 2*m pulse thyristor rectifier with R-L load |
|
Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse 2*m pulse thyristor center tap rectifier with R-L load and voltage |
|
ThyristorCenterTap2mPulse_RLV_Characteristic Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2mPulse Characteristic of 2*m pulse center tap thyristor rectifier with R-L load and voltage |
|
Modelica.Electrical.PowerConverters.Examples.DCAC.SinglePhaseTwoLevel Single phase DC to AC converter with R-L load |
|
Modelica.Electrical.PowerConverters.Examples.DCDC.ChopperStepDown Step down chopper with R-L load |
|
Modelica.Electrical.PowerConverters.Examples.DCDC.HBridge H bridge DC/DC converter with R-L load |
|
Modelica.Electrical.PowerConverters.Examples.DCDC.HBridge H bridge DC/DC converter with DC drive |
|
ThreePhaseTransformerWithRectifier Modelica.Magnetic.FluxTubes.Examples.Hysteresis 3 Phase transformer (including hysteresis effect) with rectifier |
|
Modelica.Magnetic.FundamentalWave.Examples.Components Single phase inductance |
Modelica.Electrical.Analog.Examples.Utilities Input/output block of a direct inductor model |
|
Modelica.Electrical.Analog.Examples.Utilities Input/output block of an inverse inductor model |
|
Modelica.Electrical.Analog.Lines Lossy Transmission Line |
|
Modelica.Electrical.Machines.BasicMachines.AsynchronousInductionMachines Asynchronous induction machine with slipring rotor |
|
Modelica.Electrical.Machines.BasicMachines.SynchronousInductionMachines Electrical excited synchronous induction machine with damper cage |
|
Modelica.Electrical.Machines.Interfaces Partial model for induction machine |
|
Modelica.Electrical.MultiPhase.Basic Ideal linear electrical inductors |
|
Modelica.Electrical.PowerConverters.Examples.DCDC.ExampleTemplates Step up chopper including control |
|
Modelica.Magnetic.FluxTubes.Examples.MovingCoilActuator.Components Simple behavioural actuator model for system simulation |
|
Modelica.Mechanics.MultiBody.Examples.Systems.RobotR3.Components Motor model including current controller of r3 motors |