| ThyristorCenterTap2mPulse_RL2*m pulse thyristor rectifier with R-L load |  | 
This information is part of the Modelica Standard Library maintained by the Modelica Association.
This example shows a controlled 2*m pulse center tap rectifier with R-L load, where m is the number of phases.
Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.
| Vrms | Value: 110 Type: Voltage (V) Description: RMS supply voltage | 
|---|---|
| f | Value: 50 Type: Frequency (Hz) Description: Frequency | 
| constantFiringAngle | Value: 30 * pi / 180 Type: Angle (rad) Description: Firing angle | 
| R | Value: 20 Type: Resistance (Ω) Description: Load resistance | 
| L | Value: 1 Type: Inductance (H) Description: Load resistance | 
|  | ground | Type: Ground | 
|---|---|---|
|  | star | Type: Star | 
|  | sineVoltage_p | Type: SineVoltage | 
|  | rectifier | |
|  | voltagesensor | Type: VoltageSensor | 
|  | meanVoltage | Type: Mean | 
|  | rootMeanSquareVoltage | Type: RootMeanSquare | 
|  | currentSensor | Type: CurrentSensor | 
|  | meanCurrent | Type: Mean | 
|  | pulse2m | Type: VoltageCenterTap2mPulse | 
|  | sineVoltage_n | Type: SineVoltage | 
|  | resistor | Type: Resistor | 
|  | inductor | Type: Inductor |