FixedHeatFlowFixed heat flow boundary condition  | 
     | 
This information is part of the Modelica Standard Library maintained by the Modelica Association.
This model allows a specified amount of heat flow rate to be "injected" into a thermal system at a given port. The constant amount of heat flow rate Q_flow is given as a parameter. The heat flows into the component to which the component FixedHeatFlow is connected, if parameter Q_flow is positive.
If parameter alpha is <> 0, the heat flow is multiplied by (1 + alpha*(port.T - T_ref)) in order to simulate temperature dependent losses (which are given with respect to reference temperature T_ref).
| Q_flow | 
         Value: Type: HeatFlowRate (W) Description: Fixed heat flow rate at port  | 
    
|---|---|
| T_ref | 
         Value: 293.15 Type: Temperature (K) Description: Reference temperature  | 
    
| alpha | 
         Value: 0 Type: LinearTemperatureCoefficient (ยน/K) Description: Temperature coefficient of heat flow rate  | 
    
| port | 
         Type: HeatPort_b  | 
    
|---|
| 
        
         Modelica.Fluid.Examples Simple model of a heating system  | 
    |
| 
        
         Modelica.Fluid.Examples Multi-way connections of pipes and incompressible medium model  | 
    |
| 
        
         Modelica.Fluid.Examples Multi-way connections of pipes with dynamic momentum balance, pressure wave and flow reversal  |