SpeedForced movement of a flange according to a reference angular velocity signal |
This information is part of the Modelica Standard Library maintained by the Modelica Association.
The input signal w_ref defines the reference speed in [rad/s]. Flange flange is forced to move relative to flange support according to this reference motion. According to parameter exact (default = false), this is done in the following way:
The input signal can be provided from one of the signal generator blocks of the block library Modelica.Blocks.Sources.
useSupport |
Value: false Type: Boolean Description: = true, if support flange enabled, otherwise implicitly grounded |
---|---|
exact |
Value: false Type: Boolean Description: Is true/false for exact treatment/filtering of the input signal, respectively |
f_crit |
Value: 50 Type: Frequency (Hz) Description: If exact=false, critical frequency of filter to filter input signal |
Modelica.Electrical.Machines.Examples.SynchronousMachines Test example: ElectricalExcitedSynchronousMachine with voltage controller |
|
Modelica.Electrical.Machines.Examples.SynchronousMachines Test example: ElectricalExcitedSynchronousMachine with rectifier |
|
Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.SynchronousMachines Test example: ElectricalExcitedSynchronousMachine with voltage controller |
|
Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.SynchronousMachines Test example: ElectricalExcitedSynchronousMachine with rectifier |
|
Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.InductionMachines Characteristic curves of Induction machine with squirrel cage |
|
Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.InductionMachines Characteristic curves of induction machine with slip rings |
|
Modelica.Thermal.FluidHeatFlow.Examples Cooling circuit with pump and valve |
|
Modelica.Thermal.FluidHeatFlow.Examples Water pumping station |